Supero SMT IPMI User Manual page 29

Smt ipmi
Hide thumbs Also See for Supero SMT IPMI:
Table of Contents

Advertisement

To Setup an Alert
1
2
3
4
5
6
Follow the steps below to setup an alert.
1. Select Alerts from the window on the left.
2. Select Alert Severity.
3. Enter the SNMP Trap receiver (i.e. IPMI View) IP address to use SNMP. For
further guidance on typical inquiries relating to SNMP, see the table below.
Item
SNMP version number
MIB community name
MIB file location
The IPMI item you need to con-
figure so the SNMP manager
can receive the SNMP trap
Can I query for detailed infor-
mation on the MIB "Event" trap
items?
A list of trap items generated for
my platform
Chapter 2: Configuring BMC/IPMI Settings
7
Answer
SNMP version 2.
A community name is not required since
SNMP version 2 only uses traps.
Go to http://www.supermicro.com/products/
nfo/IPMI.cfm and click "IPMI MIB (SMT)"
(right-hand side of the page).
The alert LAN destination address (see #4
under 2.4.1) must be set to the same IP in
as the SNMP manager.
Detailed queries are not possible because
event mapping is based only on sensor
type, event type, and sensor offset.
No standard list of event traps exist be-
cause the PEF (Platform Event Filter) table
is OEM customizable.
2-17