Is an application that allows you to send and receive email directly from a touch panel connected to a netlinx™ control system, and utilizes a graphics email program to send and receive email from any standard pop3 email account (18 pages)
Page 1
Operation/Reference Guide IREdit IR Library Management D e v e l o p m e n t T o o l s L a s t R e v is e d : 1 / 2 3 / 2 0 1 2...
Page 2
AMX is not responsible for products returned without a valid RMA number. AMX is not liable for any damages caused by its products or for the failure of its products to perform. This includes any lost profits, lost savings, incidental damages, or consequential damages.
Table of Contents Table of Contents IREdit IR Library Management ................1 Overview ........................1 Supported Platforms....................1 The IREdit Work Area ....................2 Menus ........................3 File Menu ........................3 Edit Menu........................4 View Menu ........................4 Tools Menu........................5 Window Menu .........................
Page 4
Actuate IR ....................... 28 Actuating an IR Function ....................28 Restore Default Window Settings................29 IR Update Wizard....................30 AMX IR Database Update ..................... 31 Web Update ......................31 Navigating using the Windows dialog ..............32 To Activate a Window ....................32 To Close a Window......................
Page 5
Virtual NetLinx Master Transfers ................41 Configure the Touch Panel for Virtual NetLinx Master Transfers ........41 Configuring IREdit for Virtual NetLinx Master Transfers ..........42 Powering Up and Connecting the Panel................ 42 Transferring Files Using a Virtual NetLinx Master Connection ........42 Receiving an IR File ....................
Page 6
Table of Contents IREdit IR Library Management...
IREdit implements a new database file type, .IRN, that can also be used in NetLinx Studio. An .IRN database file is created when you create a new user database within IREdit. IREdit also provides the (read-only) AMX database containing IR files for many popular devices.
Search window FIG. 1 IREdit Work Area The IREdit work area consists of individual windows which are able to be docked, moved and resized as desired. Below are the common windows found during a session. IREdit Work Area Components Item...
Provides the option of creating a New Database or new Hand Control. Open Initiates the Open dialog, where you can locate and open the desired database (.IRN) Note: You can initiate an IREdit session by simply double-clicking on an .IRN, .IRV or .IRL in Explorer. Save Copy As Saves a copy of the currently selected database as a new .IRN file, under a user...
IREdit IR Library Management Edit Menu FIG. 3 Edit Menu The Edit menu contains options relating to editing files and categories. Edit Menu Undo/Redo Undo and Redo the last action. Cut the selected text or slot to the clipboard. Copy Copy the selected text or slot to the clipboard.
Tools Menu Send Sends an IR to a designated Master location. Receive Transfers an IR from a designated Master into IREdit. Verify Checks the file integrity after a transfer. Identify Allows you to identify functions in a list of hand controls via the Identify dialog.
Description Web Update Launches the AMX Web Update utility. About Displays the about IREdit dialog containing information pertaining to version and copyright. Standard Toolbar Click any of the icons for a quick step to commonly used functions: Standard Toolbar Items...
IREdit IR Library Management IREdit Windows Working With Dockable Windows All windows are both collapsible and able to be docked, moved and resized: Click on the thumb tack button located in the top right of each window to collapse the window down to a tab located on the side of the screen (FIG.
IREdit IR Library Management If a template has been applied to the IR file, the corresponding value appears in the Template column. Tabs with the hand control file's names are present at the top of the IR Document window, allowing you to easily switch between hand control files when more than one are open.
IREdit IR Library Management Properties Window Context Menu (Cont.) Paste • Pastes the selected text from the clipboard to the new text field location. Delete • Deletes the selected text. Select All • Selects all text within the field. Templates Within the Properties window you can select to apply a template.
Expands the database one level down. Expand All Expands the database down completely. Note: The AMX database can only Expand All from the model level down; user databases can only Expand All from the category level down. Close Closes the selected database.
IREdit IR Library Management Search Window Select View > Search to show the Search window (FIG. 13). FIG. 13 Search Window The Search window allows you to search for an IR hand control file within a specified database by Manufacturer, Category, Model, Hand Control, Version, Function Name, and/or Function Number.
IREdit IR Library Management Quick List Window The Quick List window provides a read-only list of available functions for the currently selected hand control file. FIG. 15 Quick List Window This list is displayed automatically (as long as the Quick List window is activated via the View menu), and does not require that the hand control file be open in a IR Document window.
Basic Operations Creating a New IR Database The AMX database (.IRNs) is read only. If you want to construct or edit any IR hand controls you must first create a new database file. Select File > New > New Database to launch the New File dialog (FIG. 16).
Basic Operations Creating a New Hand Control File IREdit utilizes wizards to step assist in creating new IR files. Select File > New > Hand Control to access the New Hand Control Wizard (FIG. 18): FIG. 18 New Hand Control Wizard - Welcome dialog You must have a user-created Database file open in the Navigator to enable the File >...
Page 21
Alternatively, you can type a new category in the text field above the list, if none of the listed categories adequately describe the target device type. Click Next to proceed to the Model dialog (FIG. 21): Enter the model number of the device that the selected hand control will control in the text field. IREdit IR Library Management...
Page 22
Click Next to proceed to the Hand Control dialog (FIG. 22): FIG. 22 New Hand Control Wizard - Hand Control dialog Enter the model number of the selected hand control in the text field. Click Next to proceed to the Finished dialog (FIG. 23): IREdit IR Library Management...
Once all fields are populated with information, the Finish button is enabled. Click Finish to save the changes and close the New Hand Control Wizard (Advanced options) dialog. The hand control file is generated and added to the open User Database file (visible in the Navigator window). IREdit IR Library Management...
Select one or more hand controls in the Search Results window and click Tools > Identify to open the Identify dialog (FIG. 26): . FIG. 26 Identify Dialog The Identify dialog contains a listing of selected table columns: IREdit IR Library Management...
Click on the Capture button to begin the identification session (FIG. 28): FIG. 28 Identify dialog - Capture and remove Not Hit buttons Begin sending functions to IREdit via the IRIS. As the functions are received, found functions will be moved to the top of the list.
Cut, Copy And Paste Databases User defined databases can be both cut and pasted into other user defined databases. Conversely, the AMX database can only be copied. If you are pasting into a new database an entire product hierarchy must first be established.
IR function. See the Waveform Window section on page 9 for details. Editing IR Files IREdit allows you to edit up to 255 functions within user-created IR files. IR files contained within the AMX Database cannot be edited. ...
Select a user database file in the Navigator window. Select Edit > Categories to open the Category Manager dialog. Select the category you want to delete. Click on the Delete button. Once finished, click on the Close button. IREdit IR Library Management...
(FIG. 32): FIG. 32 Model Manager Dialog You can only edit directories you have created. The AMX database is read-only. Select Add and a new model line will appear (FIG. 33): FIG. 33 Model Manager Dialog - New Model Entry Place the cursor in the Model field and enter a model name.
Afterwards you are returned to Model Manager. Click OK. Capturing An IR File With the use of an IRIS, IREdit can capture IRs into hand control functions specified by you. IRIS Infrared/Serial Data Capture Unit The IRIS Infrared Capture Unit is a stand-alone, self-contained unit captures infrared (IR) or wired-IR function signals from an IR hand control.
IREdit utilizes the base format (raw oscillated code) of the hex codes (available at www.remotecentral.com). Discreet hex codes can be imported into IREdit files via the Discrete IR Hex Codes Wizard. Select Tools > Discrete IR Hex Codes to open the Discrete IR Hex Codes Wizard dialog (FIG. 36): FIG.
IREdit will attempt to translate the text into the AMX proprietary IR format and write it to the selected function in the .IRN/.IRV file in the same manner as the IRIS capture functionality currently operates.
Discreet IR hex-format codes must be either raw oscillated code (first four-byte block = 0000) or raw unmodulated code (first four-byte block = 0100) in order to be translated into the AMX proprietary format. Importing IR Files You have the option of importing any of your preexisting .IRL files into a user defined database Select the destination database in the Navigation window for the .IRL files.
Generated Filename. (Manufacturer,Device,HandcontrolModel,Category,version.irl) use the DOS filename (only available when exporting from the AMX database) or naming the file yourself. In the Directory to export to field, designate a target directory for the exported.IRL file (browse to a new directory by selecting the browse button).
Press to manually actuate the selected IR function from OFF to ON. Click the Off button to turn on the corresponding LED at the master. To actuate other ports, exit back to the IREdit work area and repeat the process. Restore Default Window Settings This restore feature returns all of IREdit's dockable windows to the default arrangement.
Basic Operations IR Update Wizard The IR Update Wizard takes you through the steps necessary to downloading available updates for the AMX IR database. An internet connection is required Select Help > AMX IR Update to open the IR Update Wizard (FIG. 42): FIG.
After the update is complete, the AMX IR database will collapse. Web Update Newer versions of IREdit can now be acquired via the internet. The Web Update utility accesses the AMX web site with the application ID and version number and searches for updates.
Choose File > Print Preview to open the Print Preview window (FIG. 46), to preview the file as it will be printed (if necessary). FIG. 46 Print Preview window Choose File > Print to print the file. IREdit IR Library Management...
The options in this menu allow you to make any of the following modifications to the selected toolbar button: Reset - Returns all values of the command to the default settings. Delete - Removes the command from the toolbar. IREdit IR Library Management...
The Preferences dialog allows for behavioral changes to be made to the application. FIG. 48 Preferences Dialog Undo/Redo Support No undo/redo support is available unless it is enabled in the Preferences dialog. To enable: Go to Edit > Preferences... IREdit IR Library Management...
Under IRCapture place a check in the box next to Auto Template Capture. Click the OK button. Skip Finish Page When enabled IREdit will skip the Finish page of the IR capture process and instead return to the Start page of IR capture. Go to Edit > Preferences...
Page 42
Advanced Operations IREdit IR Library Management...
User Name and Password button - click to open the Master Controller User Name and Password dialog (FIG. 50): FIG. 50 Master Controller User Name and Password dialog Enter the required login credentials and click OK. IREdit IR Library Management...
Click the down arrow to open a menu where you can choose the Stop bit(s) (suggested setting = 1). Flow Control Click the down arrow to open a menu where you can choose the Flow Control (suggested setting = none). IREdit IR Library Management...
Virtual NetLinx Master Settings dialog With Virtual NetLinx Master selected as the Transport Connection Option, click Settings in the Communications Settings dialog to open the Virtual NetLinx Master Settings dialog (FIG. 53): FIG. 54 Virtual NetLinx Master Settings dialog IREdit IR Library Management...
Select an IR File in the Navigator window (FIG. 55): FIG. 55 IR FIle selected in the Navigator window Select Tools > Send or click the toolbar button. This action prompts IREdit to make the device connection specified in the Communications Settings dialog (FIG. 56). FIG. 56 Connecting dialog Once the connection has been established, the Send IR dialog is opened (FIG.
Virtual NetLinx Master Transfers IREdit supports direct connection to G4 panels (via USB), for situations where the target panel is not connected to a NetLinx Master. In this situation, you can use your PC's USB connection to connect directly to the panel, using your PC as a Virtual NetLinx Master.
Transferring Files Using a Virtual NetLinx Master Connection Once you have configured both the touch panel and IREdit for Virtual NetLinx Master Transfers, you are ready to transfer files to the panel without the need for an intermediate master: With your IR file selected in the Navigator window, select Tools >...
Receiving an IR File You can transfer a preexisting IR file from either an Axcess or NetLinx Master directly into IREdit. First select a user database in the Navigator window. If you do not have a user database you must create one.
Get Available Memory is a reflection of all 4 ports. All ports share the same available memory in Axcess. NI-series devices (NI-2000, NI-3000, NI-4000) always return the value 32768 in response to a "Get Available Memory" request, regardless of the port queried. IREdit IR Library Management...
Master. Verify will compare all functions in the hand control file on the Master’s port to the functions listed in IREdit’s hand control selected in the Navigator window. In order to verify you must first send a hand control file.
Page 52
The hand control is received from the Master. Select Next to proceed to the Finished dialog. This dialog lists the Manufacturer, Category, Device Model and Hand Control Model. The message screen below will read either, "Verification Successful" or "Verification Failed." IREdit IR Library Management...
File and View), and View (functions related to the setup of the work area). The related commands are located in the Commands window to the right of the Categories field. Selecting Description when a command is highlighted will provide information for that particular function. If the IREdit IR Library Management...
Show shortcut keys in Screen Tips - When selected, if there is a shortcut key associated with the command it will appear upon mouse over. Floating Toolbar Fade Delay (in milliseconds) - Toolbars not docked will fade partially out after your designated time and return to view when selected IREdit IR Library Management...
Menu Animations - You can choose from Fade, Slide, Unfold, Random and None for Menu Animations. Customize Keyboard Dialog Shortcut keys can be assigned and reassigned to user specified commands. FIG. 70 Customize Keyboard Dialog Categories: All Commands - This selection will display all commands under the Commands view. IREdit IR Library Management...
Page 56
Assign - Confirms changes made to commands. Remove - Deletes shortcut associated to command. Reset All - Deletes all changed shortcuts and returns them to the default settings. Close - Closes the Customize Keyboard dialog. IREdit IR Library Management...
Page 57
Setting Program Preferences IREdit IR Library Management...
Page 58
- Schedules and registration for any AMX University course - Travel and hotel information - Your individual certification requirements and progress 3000 RESEARCH DRIVE, RICHARDSON, TX 75082 USA • 800.222.0193 • 469.624.8000 • 469-624-7153 fax • 800.932.6993 technical support • www.amx.com...