Accu Spot 300
Editing procedure 3: Record the selected scenes automati-
cally from external controller:
1. Access the main menu.
2. Select "EDIT" by pressing the UP or DOWN buttons, press
ENTER.
3. Press the UP button until the display shows "STEP", press
ENTER.
4. Now adjust and set the number of steps by pressing the
UP or DOWN buttons. Press ENTER to confirm the number of
steps, and "PASS" will display briefly.
5. Now press the DOWN button until "REC" is displayed, and
press ENTER.
6. The display will now show "RE.XX", "XX" stands for the scene
number in the internal memory which the scenes from the con-
troller will be stored to. Press ENTER when you have chosen
the scene number.
7. Call up the scenes on the controller, and the fixture will
record the scenes from the controller automatically. After the
number of scenes as selected in the "STEP" menu are loaded
into the fixture, it will stop the procedure and return to the pre-
vious menu.
8. Press MODE/ESC to exit the "EDIT" menu and return to the
main menu.
American DJ
- www.americandj.com - Accu Spot 300 Instruction Manual Page 31
®
Editing Program
Accu Spot 300
When power is applied, the unit will automatically enter a
"reset/test" mode. This mode brings all the internal motors to a
home position. If there is an internal problem with one or more
of the motors an error code will flash in the display in the form
of "XXer", "XX" will represent a function number. For example,
when the display shows "02Er," it means there is some type
of error with the channel 2 motor. If there are multiple errors
during the start-up process they will all flash in the display. For
example: if the fixtures has errors on channel 1, channel 2, and
channel 3 all at the same time, you will see the error message
flash "01Er", "02Er," and "03Er" repeated 5 times.
If an error does occur during the initial start-up procedure the
fixture will self-generate a second reset signal and try to realign
all the motors and correct the errors, if the errors persist after a
second attempt a third attempt will be made.
If after a third attempt all the errors have not been corrected the
fixture will make the following determinations:
1) 3 or more errors - The fixture cannot function properly with
three or more errors therefore the fixture will place itself in a
stand-by mode until subsequent repairs can be made.
2) Less than 3 errors - If the fixture has less than 3 errors, there-
fore most other functions will work properly. The fixture will
attempt to operate normally until the errors can be corrected by
a technician. The errors in question will remain flashing in the
display as a reminder of internal errors.
01Er – PAN movement error:
If the yoke is not located in the default position after start-up or
after a reset command. This message will appear after a fixture
reset, if the pan-yoke's magnetic-indexing circuit malfunctions
(sensor failed or magnet is missing) or there is a stepper motor
failure (defective motor or a defective motor IC drive on the
main PCB).