Input Programming

Remote Call-In:
The IS-IPRY8 adaptor has 4 inputs. These inputs can be programmed to trigger a call-in from a specifi c
door station to a specifi c master station or group of master stations (max. 20). The IS-IPRY8 inputs can
have different calling rules than the default calling rule set under advanced stations settings in the IS Host
Programming.
Choose the priority for each input using the drop down box. Enter the target IP address of the door station
for remote call-in.
After the call priority level and target IP address have been set, click Apply Settings at the bottom of the
screen to save the settings to memory. Return to the application screen or reboot adaptor by clicking on the
Reboot button. Rebooting must occur to apply changes to adaptor.
To select which master stations will receive remote call-in, click on the Destinations button. A new window
will open. Enter the TermID for each master station to trigger (see page 4 for TermID information). Check
the Enable box beside each TermID entered to allow the master to be called. Once all master station
TermID's have been entered and enabled, click Apply Settings at the bottom of this window to save the
settings to memory. Reboot to update adaptor settings.