Monitoring For Protocol Failure And Recovery During Test - Agilent Technologies 8922M User Manual

Gsm test set
Table of Contents

Advertisement

Messages

Monitoring For Protocol Failure And Recovery During Test.

Monitoring For Protocol Failure And Recovery During
Test.
The Agilent 8922M/S provides error reporting for protocol errors. These errors may
be due to mobile failure, base station failure or a faulty user configuration. It is wise
to query the error messages periodically. Particularly errors should be queried prior
to call setup, after call termination and after a handover.
When the error: 'Call disconnected: PH Error: 0x009d' (or 0x009f) is encountered,
a fatal protocol error has been detected by the Agilent 8922M/S and it has
reconfigured back to the BCCH. Testing may resume from a point at which the
mobile is camped.
When the error: 'Call disconnected: PH Error: 0x009e' (or 0x00a0) is encountered,
a fatal protocol error has been detected which requires cycling power on the Agilent
8922M/S.