Follett ER400A Installation, Operation & Service Manual page 8

- 220v 60hz/230v 50hz icemakers
Table of Contents

Advertisement

Before turning power on
1. Clean and sanitize ice storage bin in accordance with cleaning procedure in ice storage bin installation
information packed with ice storage bin.
2. Turn water to icemaker on.
3. Remove cover on float reservoir.
4. Push down on float to force water out overflow tube and into evaporator drain pan.
5. Check that water drains freely from evaporator drain pan.
6. Lift float and check that float valve shuts off incoming water when raised.
After turning power on
1. Turn power to icemaker on and confirm that gearmotor, compressor and
fan motor start immediately.
2. Check that ice begins to enter bin within approximately 10 minutes.
3. With icemaker running, check that float reservoir water level is approximately 10mm (3/8") below internal
overflow and adjust to this level (raised line on side of reservoir) if necessary.
4. After making ice for 10 minutes, put ice against ice level control stat cap tube and check that icemaker
shuts down.
5. Warm ice level control stat with your fingers and check that icemaker restarts in approximately 20 minutes.
(Bin must be calling for ice.)
8

Advertisement

Table of Contents
loading