A1.2 Al Function Block - YOKOGAWA vigilantplant EJA Series User Manual

Eja series differential pressure/pressure transmitter fieldbus communication type
Table of Contents

Advertisement

Relative
Index
Parameter Name
Index
46
1046
DEVICE_STATUS_2
47
1047
DEVICE_STATUS_3
48
1048
DEVICE_STATUS_4
49
1049
DEVICE_STATUS_5
50
1050
DEVICE_STATUS_6
51
1051
DEVICE_STATUS_7
52
1052
DEVICE_STATUS_8

A1.2 Al Function Block

Index
Index
Relative
AI1
AI2
Index
0
4000
4100
1
4001
4101
2
4002
4102
3
4003
4103
4
4004
4104
5
4005
4105
6
4006
4106
7
4007
4107
8
4008
4108
9
4009
4109
10
4010
4110
11
4011
4111
12
4012
4112
13
4013
4113
Factory
Default
0
0
0
0
0
0
0
Parameter Name
Factory Default
Block Header
TAG: "AI1" or
"AI2"
ST_REV
TAG_DESC
(blank)
STRATEGY
1
ALERT_KEY
1
MODE_BLK
AUTO
BLOCK_ERR
PV
OUT
SIMULATE
Disable
XD_SCALE
Specified at the
time of order
OUT_SCALE
Specified at the
time of order
GRANT_DENY
0
IO_OPTS
0
APPENDIX 1. LIST OF PARAMETERS FOR EACH BLOCK OF THE EJA
Write
Mode
Device status (failure or setting error etc.)
Device status (function block setting.)
Not used for EJA.
Not used for EJA.
Not used for EJA.
Not used for EJA.
Not used for EJA.
Write Mode
Block Tag
Information on this block such as Block Tag, DD
= O/S
Revision, Execution Time etc.
The revision level of the static data associated with
the function block. The revision value will be
incremented each time a static parameter value in
the block is changed.
AUTO
The user description of the intended application of
the block.
AUTO
The strategy field can be used to identify grouping
of blocks. This data is not checked or processed by
the block.
AUTO
The identification number of the plant unit. This
information may be used in the host for sorting
alarms, etc.
AUTO
The actual, target, permitted, and normal modes of
the block.
This parameter reflects the error status associated
with the hardware or software components
associated with a block. It is a bit string, so that
multiple errors may be shown.
Either the primary analog value for use in executing
the function, or a process value associated with it.
May also be calculated from the READBACK value
of an AO block.
Value =
The primary analog value calculated as a result of
MAN
executing the function.
AUTO
Allows the transducer analog input or output to the
block to be manually supplied when simulate is
enabled. When simulation is disabled, the simulate
value and status track the actual value and status.
O/S
The high and low scale values, engineering units
code, and number of digits to the right of the
decimal point used with the value obtained from the
transducer for a specified channel. Refer to Table
5.15 for the unit available.
O/S
The high and low scale values, engineering units
code, and number of digits to the right of the
decimal point to be used in displaying the OUT
parameter and parameters which have the same
scaling as OUT.
AUTO
Options for controlling access of host computers
and local control panels to operating, tuning and
alarm parameters of the block.
O/S
Options which the user may select to alter input and
output block processing
A-3
Explanation
Explanation
IM 01C22T02-01E
TA0101-3EPS
TA0102-1.EPS