Installation; Mounting; Mounting The Diaphragm Seals - YOKOGAWA Dpharp vigilantplant EJA Series Manual

Eja series differential pressure and pressure transmitters
Hide thumbs Also See for Dpharp vigilantplant EJA Series:
Table of Contents

Advertisement

3.

Installation

IMPORTANT
• When welding piping during construction, take
care not to allow welding currents to flow through
the transmitter.
• Do not step on this instrument after installation.
• For EJA430A, the atmospheric opening is located
on the low pressure side cover flange. For
EJA530A with Measurement span code A, B, and
C, the pipe is attached for the opening. These
openings must not face upward.
Pipe
(Open to atmosphere)
Measurment span code
Figure 3.1
EJA530A Horizontal Mounting
Position
3.1

Mounting

■ The transmitter can be mounted on a nominal
50 mm (2-inch) pipe using the mounting bracket
supplied, as shown in Figure 3.2 and 3.3. Tighten the
(four) bolts that hold the transmitter with a torque of
approximately 39 N·m {4 kgf·m}.
Mounting bracket
Transmitter
mounting bolt
Figure 3.2
Transmitter Mounting
(Horizontal Impulse Piping Type)
Process connector upside
Mounting
bracket
Transmitter
mounting bolt
Figure 3.3
Transmitter Mounting
(Vertical Impulse Piping Type)
Zero-adjustment screw
F00301.ai
F0302.ai
Process connector downside
F0303.ai
<3. Installation>
U-bolt (S)
U-bolt nut (L)
Mounting bracket
50 mm(2-inch) pipe
Figure 3.4
EJA510A and EJA530A Mounting
3.2
Mounting the Diaphragm
Seals
IMPORTANT
• Please use a gasket which has a bigger inside
diameter than that of gasket facing (ød) on
diaphragm seal. In case a gasket which has a
smaller inside diameter than that of gasket facing
is used, it may cause an error as the gasket
prevents diaphragm from working correctly
• During the diaphragm seal installation, ensure as
far as possible that no seal liquid head is applied to
the diaphragm seals.
• Exercise care so as not to damage diaphragm
surfaces. Since the diaphragm protrudes approx.
1mm from the flange surface, placing the
diaphragm seals with their diaphragm surfaces
facing downward may damage the diaphragm
surfaces.
• Do not sharply bend or twist capillary tube or apply
excessive stress to them.
• Never loosen the four screws securing the cover
flange or the screws at the joints between the
capillary tube and cover flanges (if the seal liquid
leaks, the transmitter cannot be used).
15
Adapter
U-bolt nut (S)
U-bolt (L)
F0304.ai
IM 01C22A01-01E
3

Advertisement

Table of Contents
loading

Table of Contents