Press I to store the change. The Meter beeps to signal that the change has been
3.
stored. With each press of I, the menu moves to the next parameter. To exit the
Setup menu without changing subsequent parameters, press P, V, or F.

Clearing Sample Data

The Meter stores data that periodically will need to be cleared. Individual samples or the
entire data memory can be cleared. When the memory is full (99 samples), it shows "Full"
on the display when I is pressed and the Meter emits short beeps and will not save any
value unless some samples are cleared.
To clear individual sample data, do the following:
Press either P, V, or F to clear samples for that mode.
1.
Press A.
2.
Press H(CLEAR).
3.
Use D and E to select the desired sample number. The last measurement
4.
saved appears first.
Press I to clear the sample. Note that the number of samples displayed is reduced.
5.
To clear all sample data, do the following:
Press A.
1.
Press G(CLEAR ALL).
2.