TECHNICAL GUIDE
Problems
Swinging the watch
while the power save
function is active will not
activate the time relay
function. (Swinging the
watch starts the second
hand moving at two-
second intervals.)
Swinging the watch
while the power save
function is active will not
activate the time relay
function. (Swinging the
watch will not start the
second hand moving at
all.)
After the time relay
function is activated,
the hands do not make
the quick movement
smoothly, or the hands
indicate a time that
differs greatly from the
correct time.
The date numeral does
not appear in the center
of the calendar frame.
* For the troubleshooting of such defects as conventional quartz watches have in common, refer to the
"TECHNICAL GUIDE, GENERAL INSTRUCTIONS".
Possible causes
1) The energy stored in the
rechargeable battery has
been depleted while the
power save function is in
operation.
1) There is electric leakage
inside the hour and minute
coil block.
1) There is electric leakage
inside the hour and minute
coil block.
1) As the date driving wheel
spring is deformed, the date
driving wheel does not
contact with the intermediate
date driving wheel, thus
making the date driving
wheel turn irregularly.
Methods of repair and checking
1) Swing the watch until the second hand
moves at one-second intervals, and
activate the power save function
manually to check if the time relay
function can be activated.
1) Check for leakage of the hour and minute
coil block. Replace the part if leakage is
detected.
1) Check for leakage of the hour and minute
coil block. Replace the part if leakage is
detected.
1) Correct the deformation of the date
driving wheel spring. Replace the date
driving wheel if it is deformed to the
extent that the correction is impossible.
Cal. 5J32A
See the
page below.
Page 18
Page 15
Page 15
Page 9
21