3.4

Drive mounting

You can mount the drive using four screws in the side-mounting holes or four screws in the bottom-mounting
holes. See Figure 4 for drive mounting dimensions. Follow these important mounting precautions when mount-
ing the drive:
• Allow a minimum clearance of 0.030 inches (0.76 mm) around the entire perimeter of the drive for cooling.
• Use only M3 UNC mounting screws.
• Do not overtighten the mounting screws. Maximum torque: 4.0 inch-lb (0.4519 N-m).
• Four (4) threads (0.080 inches, 2.032 mm) minimum screw engagement recommended.
• Avoid excessive drive distortion when mounting.
Measurements shown in Figure 4 are in inches.

Figure 4. Mounting dimensions

Momentus 5400 FDE.3 SATA Product Manual, Rev. A
3.95 +/- .010
Breather Hole
Do not cover
+
or seal.
Recommended
case temperature
measurement
location