C. Performance Data

1. KM-515MAH (air-cooled)

APPROXIMATE ICE
PRODUCTION PER 24 HR.
lbs./day kg./day
APPROXIMATE ELECTRIC
CONSUMPTION
watts
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
3
gal./day
m
/day
FREEZING CYCLE TIME
min.
HARVEST CYCLE TIME
min.
HEAD PRESSURE
2
PSIG
kg/cm
G
SUCTION PRESSURE
2
PSIG
kg/cm
G
TOTAL HEAT OF REJECTION FROM CONDENSER
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold
should be used for reference only.
2. We reserve the right to make changes in specifications and design without prior
notice.
AMBIENT TEMP.
(ºF/ºC)
70/21
501
80/27
486
90/32
482
100/38
472
70/21
80/27
90/32
100/38
70/21
188
80/27
168
90/32
162
100/38
132
70/21
80/27
90/32
100/38
70/21
80/27
90/32
100/38
70/21
226
80/27
244
90/32
250
100/38
254
70/21
45
80/27
48
90/32
49
100/38
50
WATER TEMP. (ºF/ºC)
50/10
70/21
227
482
221
456
218
435
214
426
980
1012
1005
1055
1090
1012
1011
1095
0.71
162
0.64
128
0.61
99
0.50
97
26
27
27
30
32
27
28
33
4.4
3.9
4.0
3.2
3.9
2.7
3.4
2.7
15.9
250
17.2
282
308
17.6
17.8
314
3.2
49
3.4
55
3.5
59
3.5
60
9,600 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
30
90/32
218
447
203
207
416
189
197
396
180
193
361
164
1038
1071
1111
1130
0.61
147
0.56
0.48
124
0.47
0.38
90
0.34
0.37
82
0.31
30
33
35
37
3.8
3.4
2.7
2.7
17.6
278
19.5
19.8
306
21.5
21.7
335
23.5
22.1
359
25.2
3.5
54
3.8
3.8
60
4.2
4.1
64
4.5
4.2
69
4.9