Cleaning Procedure - Hoshizaki KM-515MAH Service Manual

Modular crescent cuber
Hide thumbs Also See for KM-515MAH:
Table of Contents

Advertisement

1. Cleaning Procedure

1) Dilute 16 fl. oz. (473 ml) of Hoshizaki "Scale Away" with 3 gal. (11 l) of warm water.
2) Remove all ice from the evaporator and the storage bin.
Note: To remove cubes on the evaporator, turn off the power supply and turn it back on
after 3 minutes. The harvest cycle starts and the cubes will be removed from the
evaporator.
3) Turn off the power supply.
4) Remove the front panel and the base cover,
and then remove the insulation panel by
lifting up the panel slightly and pulling it
towards you.
5) Remove one end of the pump tubing. See
Fig. 4. Drain the water tank. Replace the
pump tubing in its correct position.
6) In bad or severe water conditions, clean the float switch assembly as described below.
Otherwise, continue to step 7.
a. Disconnect the vent tube and the flush tube from the top of the float switch, then
remove the float switch and rubber boot.
b. Remove the retainer rod from the bottom of the float switch assembly, then remove
the float. Be careful not to bend the retainer rod excessively when removing it.
c. Wipe down the float switch assembly's housing, shaft, float, and retainer rod with
cleaning solution. Clean the inside of the rubber boot and hose with cleaning
solution. Rinse the parts thoroughly with clean water.
d. Reassemble the float switch assembly and replace it and the rubber boot in their
correct positions. Reconnect the vent tube and the flush tube.
7) Pour the cleaning solution into the water tank.
8) Fully open the cleaning valve on the left side wall of the machine compartment.
9) Move the control switch on the control box to the "WASH" position.
10) Replace the insulation panel and the front panel in their correct positions.
11) Turn on the power supply to start the washing process.
12) Turn off the power supply after 30 minutes.
13) Remove the front panel.
14) Remove one end of the pump tubing. Drain the water tank. Replace the pump tubing in
its correct position.
15) Move the control switch to the "ICE" position.
16) Close the cleaning valve.
Note: The icemaker will not operate unless the cleaning valve is completely closed.
17) Replace the front panel in its correct position.
18) Turn on the power supply to fill the water tank with water.
19) Turn off the power supply after 3 minutes.
Do not pull out this side.
Fig. 4
54
Pull Out
Pump Tubing

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-515mwhKm-515mrh

Table of Contents