Bin Control Check And Cleaning; Bin Control Check - Hoshizaki Serenity Series KMS-830MLH Service Manual

Modular crescent cuber including condensing unit models srk-8h/3
Hide thumbs Also See for Serenity Series KMS-830MLH:
Table of Contents

Advertisement

C. Bin Control Check and Cleaning
This unit uses a BC with a lever-actuated proximity switch to control the ice level in the
storage bin. No adjustment is required. BC is connected to CB K4 (red) connector. When
calling for ice, BC proximity switch is closed (green "BC CLOSED" LED on). When BC
actuator paddle is engaged, BC proximity switch is open (yellow "BC OPEN" LED on)
and CB shuts down the unit according to the chart below.
Cycle at
Mechanical Bin
Control Activation
Fill Cycle
Harvest Cycle
Freeze Cycle
CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are
securely in place after the unit is serviced. Make sure that none have fallen into
the storage bin.

1. Bin Control Check

To check BC, follow the steps below.
1) Turn off the power supply and clear any ice away from BC.
2) Remove the front and top panels, then move the control switch to the "OFF" position.
3) Remove the control box cover.
4) Disconnect the BC connector from CB K4 (red) connector.
5) If BC is accessible from the dispenser unit/storage bin, continue to step 6. If BC is not
accessible from the dispenser unit/storage bin, remove BC insulation. Remove BC
cover thumbscrews, then lift BC assembly out of the icemaker. See Fig. 1.
6) Check for continuity across the wires of the BC connector. When the actuator paddle
is not engaged, BC switch is closed. If open, check that BC wire harness is properly
connected to BC cable and that the actuator paddle is not sticking. Clean if necessary.
See "IV.C.2. Bin Control Cleaning." If BC switch still reads open, replace BC.
7) Press the actuator paddle, check for continuity across the wires of the BC connector.
When the actuator paddle is engaged, BC switch is open. If closed, check that the
actuator paddle is not restricted. Clean if necessary. See "IV.C.2. Bin Control Cleaning."
If BC switch still reads closed, replace BC.
8) Reconnect the BC connector to CB K4 (red) connector, then move the control switch to
the "ICE" position.
9) Turn on the power supply.
10) Check that CB green "BC CLOSED" LED turns on.
11) Allow the unit to cycle on. Press and hold the actuator paddle. CB yellow "BC OPEN"
LED turns on and the unit shuts down according to the chart above. If not, replace CB.
12) Turn off the power supply.
Shutdown
15 seconds after activation.
At the end of the harvest cycle, or up to 15 seconds into the freeze cycle if activated
at the end of the harvest cycle.
15 seconds after activation if activated at least 15 seconds before the 5-minute short
cycle protection timer terminates. Otherwise, at the end of the next harvest cycle.
WARNING
33

Advertisement

Table of Contents
loading

Table of Contents