h) Float Switch Control (S5 dip switch 1)

Factory set. Do not adjust. Otherwise, the unit will not operate correctly.
S5 dip switch 1 allows for single or double float switch applications. The KMS-830MLH
uses a single float switch.

i) Refill Counter (S5 dip switch 2 through 5)

Factory set. Do not adjust. Otherwise, the unit will not operate correctly.
S5 dip switch 2 through 5 allows for refills during the freeze cycle.
The KMS-830MLH does not refill.
D. Control Switch
The control switch has three positions: "OFF" for power off, "ICE" for icemaking, and
"WASH" to energize the pump motor when cleaning and sanitizing.
NOTICE
S5 Dip Switch Setting Single or Double Float
No. 1
OFF
ON
NOTICE
Switch Application
Single
Double
22