C. Bin Control Check and Cleaning
This icemaker uses a BC with a lever-actuated proximity switch to control the ice level in
the storage bin. No adjustment is required.

1. Bin Control Check

To check BC, follow the steps below.
1) Turn off the power supply.
2) Remove the front panel, then move the control switch to the "OFF" position.
3) Remove the top and right side panels. Remove the control box cover, then clear any ice
away from BC.
4) Check BC wire harness connections. See Fig. 1.
5) Disconnect BC connector from CB K4 (red) connector.
6) Check for continuity across the wires of BC connector. When the actuator paddle is
not engaged, BC switch is closed. If open, check that the wire harness connector is
properly connected and that the actuator paddle is not sticking. Clean if necessary. See
"IV.C.2. Bin Control Cleaning." If BC switch still reads open, replace BC.
7) Press and hold the actuator paddle; check for continuity across the wires of BC
connector. When the actuator paddle is engaged, BC switch is open. If closed, check
that the actuator paddle is not restricted. Clean if necessary. See "IV.C.2. Bin Control
Cleaning." If BC switch still reads closed, replace BC.
8) Reconnect BC connector to CB K4 (red) connector, then move the control switch to the
"ICE" position. Turn on the power supply.
9) Check that the green "BC CLOSED" LED on CB is on.
10) Allow the icemaker to cycle on. Press and hold the actuator paddle. The yellow "BC
OPEN" LED should be on and the icemaker should shut down according to the chart
below. If it does not, replace CB.
Cycle at Bin
Control Activation
Fill Cycle
Harvest Cycle
Freeze Cycle
Legend: BC–bin control; CB–control board
Shutdown
15 seconds after activation.
At the end of the harvest cycle, or up to 15 seconds into the freeze cycle if activated
at the end of the harvest cycle.
15 seconds after activation if activated at least 15 seconds before the 5-minute short
cycle protection timer terminates. Otherwise, at the end of the next harvest cycle.