3. REMOVAL AND REPLACEMENT OF COMPRESSOR

Always install a new Drier every time the sealed refrigeration system is
opened. Do not replace the Drier until after all other repair or replacement
has been made.
Note: When replacing a Compressor with a defective winding, be sure to
install the new Start Capacitor and Start Relay supplied with the re
placement Compressor. Due to the ability of the POE oil in the com-
pressor to absorb moisture quickly, the Compressor must not be
opened more than 15 minutes for replacement or service. Do not mix
lubricants of different compressors even if both are charged with
R-404A, except when they use the same lubricant.
1) Turn off the power supply and unplug the dispenser.
2) Remove the panels.
3) Remove the Terminal Cover on the Compressor, and disconnect the Compressor
Wiring.
4) Recover the refrigerant and store it in an approved container.
5) Remove the Discharge and Suction Pipes using brazing equipment.
When repairing a refrigerant system, be careful not to let the burner flame
contact the lead wires or insulation.
6) Remove the Hold-down Bolts, Washers and Rubber Grommets.
7) Slide and remove the Compressor. Unpack the new Compressor package. Install the
new Compressor.
8) Attach the Rubber Grommets of the prior Compressor.
9) Sandpaper the Suction, Discharge and Process Pipes.
10) Place the Compressor in position, and secure it using the Bolts and Washers.
11) Remove plugs from the Suction, Discharge and Process Pipes.