INSTALLING
FURNACE
(Continued)
201842
Installing
in Masonry
Wall
You can mount both models in a masonry wall. Follow the steps below to install.
1. Cut opening in wall. Make opening 14 1/4" wide by 13 5Is" high for 25,000
Btu/Hr models. Make opening 20 5h6" wide by 14 3/8" high for 40,000 Btu/Hr
models. IMPORTANT'. You must install furnace horizontally.
Do not install
furnace vertically.
2. Secure furnace to wall with toggle bolts or hook bolts set in mortar.
3. Insert furnace into opening.
Do this from inside the room. Secure furnace to wall
with toggle bolts or hook bolts.
4. On outside of wall, caulk opening
between the cabinet and the rough edges of
opening.
You can also use mortar to seal opening.
INSTALLING
THERMOSTAT
WARNING
Unplug furnace
before installing
thermostat.
Mount the thermostat
directly on the furnace or on a wall in another
part of the
room. If you have solid or masonry
walls, mount the thermostat
on the furnace.
Mounting
Thermostat
to Furnace
1. Unplug furnace.
2. Locate red and white thermostat
wires coming out of side of furnace. These
wires are labeled "Thermostat."
3. Cut thermostat
wires to desired length.
4. Route thermostat
wires through
slot/hole
in side of thermostat
mounting
plate.
Then route wires through 5/8" diameter
hole in center of plate (see Figure 4,
page 10).
5. Connect
thermostat
wires to the two terminal
screws on back of thermostat
(see
Figure 3). Connect red wire to "R" terminal.
Connect
white wire to "W"
terminal.
White Wire
/_
j.
ir
Figure 3 - Connecting Thermostat Wires to Thermostat