Williams 4003532 Owner's Operation And Installation Manual page 14

Window wall furnace direct vent natural gas heater 25,000 and 40,000 btu/hr furnaces
Table of Contents

Advertisement

m
INSTALLING
FURNACE
(Continued)
Connecting
Fumace
to Gas Supply
at Rear of Furnace
1. Remove the two screws in back of furnace cabinet located by the exhaust
vent(s) (see Figures 9 and 10).
Figure 9 - Locations of Screws in
Back of Furnace Cabinet
(25,000 Btu/Hr Model)
Figure 10 - Locations of Screws in
Back of Furnace Cabinet
(40,000 Btu/Hr Model)
2. Remove two screws on front lower flange that attach furnace flange to furnace
cabinet flange (see Figure
11). Note: 40,000 Btu/Hr model has a bottom shield
(see parts list, page 31, for location).
Removing
two screws will detach bottom
shield.
Furnace
Cabinet Flange-
Flange
=a
Figure 11 - Removing Screws on Lower Flange (40,000 Btu/Hr Model Shown)
3. Slide furnace out of furnace cabinet.
4. Locate gas inlet pipe on lower, right front of furnace.
5. 40,000
Stu/Hr
Model
Only:
Remove
screw holding
gas inlet pipe clamp to
furnace.
6. Disconnect
gas inlet pipe from 3/8" manifold
elbow. Turn gas inlet pipe counter
clockwise
to disconnect
(see Figure
12).
Remove Screw, __"
40,000 Btu/I-Ir
Model Only
Gas Inlet
Pipe
Aanifold Elbow
Rgure 12 - Disconnecting
Gas Inlet Pipe (40,000 Btu/Hr Model Shown)
7. Rotate the 318" manifold
elbow 90 ° so the opening is pointing
downward
(see
Figure
12).