Soleus Air MAC-8000 Owner's Manual
Soleus Air MAC-8000 Owner's Manual

Soleus Air MAC-8000 Owner's Manual

8,000 btu portable air conditioner, dehumidifier and fan
Hide thumbs Also See for MAC-8000:

Advertisement

Quick Links

8,000 BTU Portable Air
Conditioner, Dehumidifier
and Fan
OWNER'S
MANUAL
Model # MAC-8000
Please read owner's manual carefully before operating
unit.

Advertisement

Table of Contents
loading

Summary of Contents for Soleus Air MAC-8000

  • Page 1 8,000 BTU Portable Air Conditioner, Dehumidifier and Fan OWNER'S MANUAL Model # MAC-8000 Please read owner's manual carefully before operating unit.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION ................................I3dPOR FANT 5_ FE G UARDS ............................. LCDI POWER CORD AND PLUG ..........................PRODUCT DIAGRAM ..............................FRONT ..................................BACK ..................................ACCES_'ORIES................................INSTALLATION ................................SELECTING THE LOCATION ........................... MOUNTING THE EXHAUST HOSE .......................... WALL MOUNTING ..............................
  • Page 3: Introduction

    INTRODUCTION Thank you for purchasingthe SoleusAir MAC-80008,000 BTU PortableAir Conditionerand Dehumidifier.This unit is designed to improve indoor livingand working comfort by providingcooling, dehumidifying,and ventilationwith minimal installation. This multi-functionalunit operates as an air conditioner,dehumidifierand fan. When operating as an air conditioner,this unit is designedfor spot cooling or cooling a roomno largerthan 150 square feet with a standard eight foot ceiling height.
  • Page 4: Lcdi Powercordand Plug

    LCDI POWERCORDAND PLUG This air conditioner is equipped with an LCDI (LeakageCurrent Detection and Interruption)powercord and plug as requiredby US NationalElectricCode 440.65. This cord consistsof a lengthof shieldedflexible cord with no terminationon the load side and a LCDI attachmentplug on the line side. The LCDI powercord and plug will removethe supply source via electricaldisconnect (circuittrip) if the nominalcurrent leakage betweenthe cord shield and either load conductorexceeds a predeterminedvalue.
  • Page 5: Productdiagram

    PRODUCTDIAGRAM FRONT A. Control panel B. Interior Louvers C. Exterior Louvers D. Casters E. Recessed Handle F. Water Bucket G. PowerCable and Plug BACK A. Hot air outlet grill B. Air inletgrill C. Filter D. DrainValve ACCESSORIES • Flexibleexhaust hose and window exhaustadapter •...
  • Page 6: Installation

    INSTALLATION SELECTING THE LOCATION Place the unit in a flat location where the air outlets are not obstructed.Place the unit at least 20" (50cm) away from a wall or other obstacle. MOUNTING THE EXHAUST HOSE Slide the square end of the exhaustduct over the hot air outlet on the back of the unit. The exhausthose should be kept as short and straightas possible.
  • Page 7: Window Kjt Installation

    HORIZONTAL WINDOW WINDOW KIT INSTALLATION The window kit is designedto fit into most standard vertical and horizontalwindows. However,it may be necessaryto modify some aspects of the installationprocess for certain window types. Open the window or slidingdoor and adjust the lengthof the window kit to fit the opening.
  • Page 8: Control Panel

    CONTROL PANEL © POWERButton Press this button to turn the unit on or off. MODE Button Press this button to select amongthe modes of cooling, dehumidifying,or fan only. FAN Button Press this button to select the desired fan speed. SWING Button Press this button to oscillate the louvers or stop oscillation.
  • Page 9: Operation

    OPERATION Plug the power cord into a properly grounded outlet. Do not connectthe unit to an outlet that is also being used for other electrical appliances. The unit will beep after two seconds, then press the on/off button to begin operation. COOLING Press the ModeButton to choose the coolingfunction.
  • Page 10: Continuous Drainage

    CONTINUOUS DRAINAGE Slide out the drain valve from the left side of the unit. Connectthe drain tube to the valve. Make sure the drain tube drains downward. Placea pan or bucket under the drain tube to hold the condensatewater,or let the tube drain down a gravitydrain. Slide out drain valve Connect...
  • Page 11: Maintenance

    MAINTENANCE Always turn off and unplugthe unit before cleaningto avoid electricalshock. CLEANING THE HOUSING Wipe the surface of the unitwith a soft, damp cloth. Do not use abrasive chemicalsor detergents to clean the surface of the unit, as the unit may become scratched or damaged.
  • Page 12: Troubleshooting

    TROUBLESHOOTING Beforeseeking repair or service, please check the following: PROBLEM POSSIBLE CAUSE REMEDY Is the unit plugged in? Securely plug the powercord into the wall outlet. Is the main powersupply on? Reestablishthe main powersupply. Unit does not operate or only runs in fan mode. Is the water bucketfull indicator light on? Empty the water bucket.
  • Page 13: Technicalspecifications

    TECHNICALSPECIFICATIONS MODEL MAC-8000 8,000 BTU/Hr Cooling Capacity DehumidifyingCapacity 75 Pints per day 850 W Power Consumption t Cooling: Dehum: 680 W Air Flow Volume 170 CFM Power Source 115V/60 HZ Rated Current 7.4A t Cooling: Dehum: 5.9A Sound PressureLevel <53 db(A)
  • Page 14: Warranty

    WARRANTY One Year Limited Warranty Soleus International Inc. warrants the accompanying Soleus Air MAC-8000 to be flee of detects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States.