Soleus Air MA-9000AH Owner's Manual
Soleus Air MA-9000AH Owner's Manual

Soleus Air MA-9000AH Owner's Manual

Soleus air portable air conditioner owner's manual
Hide thumbs Also See for MA-9000AH:

Advertisement

- Cooling
- Heating
- Dehumidifying
- Fan
Please read Owner's Manual
carefully before operating the
unit
1
.

Advertisement

Table of Contents
loading

Summary of Contents for Soleus Air MA-9000AH

  • Page 1 - Cooling - Heating - Dehumidifying - Fan Please read Owner’s Manual carefully before operating the unit...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION... 3 IMPORTANT SAFEGUARDS... 3 PACKAGE CONTENTS... 4 IDENTIFYING THE PARTS ... 4 ASSEMBLY REQUIREMENTS ...………………………………………6 CONTROL PANEL AND LCD DISPLAY ... 7 CONTROL PANEL FUNCTIONS ... 8 OPERATION USING CONTROL PANEL ... 9 OPERATION USING REMOTE CONTROLLER ... 11 CONDENSATE WATER DRAINAGE...
  • Page 3: Introduction

    INTRODUCTION Thank you for purchasing the Soleus Air MA-9000AH portable air conditioner. This unit is designed to improve living and working comfort by providing cooling, dehumidifying and fan functions with only minimum installation required. With its whisper quite operation and attractive design, you will enjoy the convenience and comfort that this unit provides for many years to come.
  • Page 4: Package Contents

    PACKAGE CONTAINS: 1 Portable Air Conditioner 1 Air Exhaust Duct 1 Window Kit (2 Sliding Panels) 1 Window Kit Adapter 1 Remote Controller 2 AAA Batteries 1 User Manual IDENTIFYING THE PARTS Front View...
  • Page 5 Exhaust Duct Window Kit...
  • Page 6: Assembly Requirements

    ASSEMBLY REQUIREMENTS Exhaust Duct When you use the unit as an air conditioner, the hot exhaust air must be directed out of the room. The exhaust duct is required to allow the hot air out of the room through a window.
  • Page 7: Control Panel And Lcd Display

    NOTE: In order to achieve maximum room cooling efficiency, the exhaust duct should remain as short and straight as possible. To further shorten the exhaust hose, first unthread either exhaust duct adapter clockwise to remove it. Then cut the hose to desired length. It is not recommended to increase the manufacturer’s length of the exhaust hose.
  • Page 8: Control Panel Functions

    Control Panel Functions 1. Power On/Off Control Starts or stops the unit 2. Temperature Setting Control Select the desired temperature setting by pressing either the recommended to set the temperature before selecting the Mode Control. 3. Mode Control Select the functions of the unit for: a.
  • Page 9: Operation Using Control Panel

    a. When the unit is On, press “Timer” Button, then press the “Time” button until the desired number of hours is displayed in the lower right corner of the display window. The unit will automatically power Off once the selected number of hours has elapsed.
  • Page 10 “Water Full” light located on the front panel will blink and the unit will not begin dehumidifying. b. If exhaust duct is attached, remove it from the rear of the air conditioner c. Plug the Power Cord to the power outlet.
  • Page 11: Operation Using Remote Controller

    OPERATION USING REMOTE CONTROLLER REMOTE CONTROLLER 1. To Set the Clock Open the back cover of the remote controller and insert two AAA batteries. When batteries...
  • Page 12 are installed or replaced, the clock is set to 12:00AM. To set present time: 2. Cooling Operation a. Be sure that the drain bucket is properly placed in the unit. If the drain bucket is not properly secured, the red “Water Full” light located on the front panel will blink and the unit will not begin cooling.
  • Page 13 “Water Full” light located on the front panel will blink and the unit will not begin dehumidifying. b. If attached, remove the exhaust duct from the back of the air conditioner c. Plug the Power Cord to the power outlet.
  • Page 14: Condensate Water Drainage

    desired number of hours is displayed in the LCD. The unit will automatically power Off once the selected number of hours has elapsed. b. When the unit is Off, press “Timer” Button, then press the “Hour” button until the desired number of hours is displayed in the LCD. The unit will automatically power On once the selected number of hours has elapsed.
  • Page 15: Maintenance

    is discharged by gravity through a drainage tube (12” length) to either an external hose (not included) or to a condensate water pump device (not included). When the unit is operating on continuous drainage mode, it can operate continuously without periodic stops to empty the water bucket.
  • Page 16: Troubleshooting

    Clean or Replace Filter a. If the air filter is clogged, the airflow volume will decrease, reducing cooling efficiency. It is recommended to clean the filter once a month or as needed. b. Push down the tab on the filter cover and pull outwards to remove the entire filter and cover.
  • Page 17: Technicalspecifications

    PROBLEM Unit does not operate Unit does not cool room In dehumidifying mode, no cool air coming out “Water Full” indicator is blinking Noise or vibration Water is leaking from unit TECHNICAL SPECIFICATIONS POSSIBLE CAUSE Unit is unplugged Drain bucket is full Water bucket not installed correctly Air exhaust is clogged...
  • Page 18: Disclaimer

    CONDUCTED INDEPENDENT TEST OF THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN. CONTACT INFORMATION Contact Customer Service at our tool free number for: Optional or Spare Parts Technical Support Warranty Claims Soleus International Inc. MA-9000AH 9000 BTU/hr 1100 W 88 Pints/Day 1120W/1350W DEHUMIDIFYING 1100W 180 CFM...
  • Page 19: Warranty

    WARRANTY Soleus International Inc. warrants the accompanying MA-9000AH Soleus Air air conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States or Canada.

Table of Contents