Thank you for purchasing a quality stainless steel or iridium canopy rangehood. We have a
high standard of quality control and each rangehood is tested and approved before it leaves
the factory.
IMPORTANT: Please read prior to installation or operation
• A l w a y s s w i t c h p o w e r o ff p r i o r t o i n s ta l l i n g , s e r v i c i n g o r c l e a n i n g t h e a p p l i a n c e .
• Never use the appliance without filters.
• Please read the notes on general cleaning, especially the filters.
• Exhaust air must not be discharged into a heating flue or wall cavity, unless the cavity is
designed for that purpose.
• Areas where the rangehood is installed that also have gas, oil or coal fired heaters, must be
well ventilated to prevent a partial vacuum in the room. This includes gas hobs. (A
partial vacuum in the room could result in too high a concentration of gas in the air).
• The appliance is supplied with an approved power cable which must not be changed. If the
supply cord of this equipment is damaged, it must only be replaced by the manufacturer
o r i t s s e r v i c e a g e n t o r s i m i l a r l y q u a l i f i e d p e r s o n i n o r d e r t o a v o i d h a z a r d .
M A I N T E N A N C E
Particular care must be taken with grease filters which must be periodically cleaned (at
least every two months). Remove the grease filters and wash them either by hand or in the
dishwasher using mild detergent. In case of Charcoal Filter, it is a disposable item and
should be replaced when cleaning the rangehood. Use lukewarm water and mild detergent
to clean stainless steel components. In high humidity and coastal environments, cleaning
should be carried out frequently.
CAUTION: Never use abrasive or oil based liquid cleaners.
USE
Care and attention should always be taken when cooking with oils, alcohol, etc; which give
off flammable vapours.
Pre-used oil is especially dangerous in this respect.
Do not use uncovered electrical grill.
To avoid possible risks of fire always comply with the maintenance instruction above.
When making the electrical connection, check that the socket has an earth connection and
that the voltage values correspond to those indicated on the rating plate inside the
appliance. The appliance must be positioned so that the electrial plug is accessible.
C O N T R O L P A N E L
I N S T A L L A T I O N O F U N I T
The unit is designed for 2.4 to 2.65 metre high ceiling. The decorative chimney cover
is telescopic and is designed for 665 to 950mm adjustment.
N o t e : D u c t i n g a c c e s s o r i e s a r e n o t s u p p l i e d . P l e a s e r e f e r t o t h e o p t i o n a l d u c t i n g k i ts .
T h e a i r o u t l e t f r o m t h e m o t o r r e q u i r e s 1 5 0 m m r o u n d d u c t i n g w h i c h r e q u i r e s 1 6 0 m m
d i a m e t e r r o u n d h o l e i n t h e c e i l i n g .
c h i m n e y.
C a r e s h o u l d b e t a k e n t o a l i g n c a n o p y w i t h d e c o r a t i v e c h i m n e y a l l o w i n g
sufficient clearance to accommodate the flexible ducting.
B e f o r e s ta r t i n g a s s e m b l y, r e a d t h e i n s t r u c t i o n s c a r e f u l l y a n d r e m o v e t h e f i l t e r s f r o m
canopy to allow access to wall mounting holes. To remove the filters, pull the relative
c a t c h a n d t i l t i n g i t d o w n w a r d s u n t i l i t d i s e n g a g e s f r o m t h e s u p p o r ts . R e v e r s e t h e s e
instructions when refitting the filters.
St a i n l e s s s t e e l / i r i d i u m i s v e r y e a s i l y d a m a g e d d u r i n g i n s t a l l a t i o n i f a b r a i d e d o r
knocked by tools.
Left Push Button
=
Light On/Off Switch
utto
Second Push B
n
=
Fan On High Speed
Third Push Button
=
Fan On Second Speed
Fourth Push Button
=
Fan On Low Speed
Fifth Push Button
=
Fan Off
T h i s h o l e w i l l b e c o v e r e d b y t h e d e c o r a t i v e
104385 issue H
ECN: 04 036

Advertisement

loading

Summary of Contents for Fisher & Paykel APEX RH900

  • Page 1 I N S T A L L A T I O N I N S T R U C T I O N APEX MODEL RH900 CQ SS NZ/AUS Code 87947 UK Code 88793 EU Code 88955 APEX MODEL RH900 CM SM NZ/AUS Code 87948 UK Code...
  • Page 2 I N S T A L L A T I O N O F T H E U N I T DUCTING RECIRCULATING OPTION OPTION 2.4 TO 2.65 METRE HIGH CEILING 200mm 700mm UNDERSIDE OF HOOD TO COOKING SURFACE WARNING: The distance between the hob and the mounting holes of the canopy to be a t l e a s t 9 0 0 m m t o e n s u r e t h a t t h e f u l l y i n s t a l l e d c a n o p y h a s a c l e a r a n c e o f 7 0 0 m m ( r e c o m m e n d e d h e i g h t ) b e t w e e n t h e l o w e r p a r t o f t h e h o o d a n d t h e c o o k i n g h o b .

This manual is also suitable for:

Apex rh900 cq ssApex rh900 cm smRh900 cq ssRh900 cm sm8794788793 ... Show all