Venting Components; Installation Of The External Wall Mounted Power Vent - Montigo R320-ST Installation & Maintenance Manual

R-series-st residential fireplace
Hide thumbs Also See for R320-ST:
Table of Contents

Advertisement

Venting Components

The following venting components and associated Montigo part
numbers are available for the EDVWSPV58:
A - Termination
EDVWSPV58
EPVF58
B - Rough-in Frame
C - Flex Sections
PFL-1 (12" Section)
PFL-2 (24" Section)
PFL-3 (36" Section)
PFL-4 (48" Section)
D - Rigid Sections
PEXT - 1 (12" m/f Section)
PXT-20 (20" section)
PEXT - 2 (24" m/f Section)
PEXT - 3 (36" m/f Section)
PEXT - 4 (48" m/f Section)
E - Elbows
PEL-90MM (m/m 90° Elbow)
PEL-90FF (f/f 90° Elbow)
PEL-90FM (f/m 90° Elbow)
PEL-45FM (f/m 45° Elbow)
F - Power Cord
EPVH10 -10 foot power cord and harness
Harnesses:
EPVH20 -20 foot power cord and harness
EPVH30 -30 foot power cord and harness
EPVH40 -40 foot power cord and harness
EPVH50 -50 foot power cord and harness
EPVH60 -60 foot power cord and harness
EPVH70 -70 foot power cord and harness
EPVH80 -80 foot power cord and harness
EPVH90 -90 foot power cord and harness
EPVH100 -100 foot power cord and harness
Connection and installation of the vent components should
adhere to the following guidelines:
■ Connect all vent sections using a minimum of three sheet
metal screws on the outer pipe flue.
■ Ensure the pipe ends male to female slide in a minimum
of 1 1/2" of overlap.
■ Ensure all runs are supported with a minimum of 3 supports
per 10' of venting.
■ When hanging/ supporting venting, ensure that 1" clearance
is maintained on all sides to any combustible material.
■ Ensure when cutting sections of rigid pipe to maintain
integrity of internal supports.
■ Place the springs, supplied with the pipe kit, between the
outer and inner pipes to keep the pipes separate and avoid
any possible hot spots.
■ Montigo recommends the use of a flex section for the final
pipe connected directly to the fireplace offering greater
flexibility of installation and absorption of movement.
■ All exterior joints in venting should be sealed with high heat
silicone RV230.
XG0772 - 030711
Installation
Installation of the EDVWSPV58 external wall mounted power vent
module.
Refer to Appendix A - Power Vent locations, to ensure the planned
Vertical Power vent location is acceptable.
The EDVWSPV58 Power Vent dimensions:
11 1/16"
11 1/16"
9.0
5
The EPVF58 Rough-in Frame dimensions:
EPVF58 DIMS (2).pdf 1 3/7/2011 9:16:30 AM
14 1/4"
4 9/16"
R320-ST & 420 ST Power Vent Indoor Gas Fireplace
11 1/16"
9 3/4"
10 9/16"
14 1/16"
12 5/16"
12 1/8"
1 1/2"
8
9 11/16"
10 9/16"
5
9.0
9 11/16"
4
ISOMETRIC VIEW
Page 15