Rockford Fosgate PUNCH 200 Operation & Installation Manual page 15

Multi-channel amplifiers
Hide thumbs Also See for PUNCH 200:
Table of Contents

Advertisement

4. Prepare a length of cable to be used for the ground connection. Strip
5/8" of insulation from the end of the cable as described above and
connect to the appropriate terminal of the amplifier. Prepare the chassis
ground by scraping any paint from the metal surface and thoroughly
clean the area of all dirt and grease. Strip the other end of the wire and
attach a ring connector. Fasten the cable to the chassis using a non-
anodized screw and a star washer.
5. Prepare the REM turn-on wire for connection to the amplifier by stripping
1/4" of insulation from the wire end and crimping an insulated spade
connector in place. Slide the connector over the REM terminal on the
amplifier. Connect the other end of the REM wire to a switched 12 volt
positive source. The switched signal is usually taken from the source
unit's auto antenna or the accessory lead. If the source unit does not
have these outputs available, the recommended solution is to wire a
mechanical switch in line with a 12 volt source to activate the amplifier.
6. Securely mount the amplifier (with supplied screws) to the vehicle or
amp rack. Be careful not to mount the amplifier on cardboard or plastic
panels. Doing so may enable the screws to pull out from the panel due
to road vibrations or sudden vehicle stops.
7. Determine the number of inputs needed to drive the amplifier and move
the input switch to the desired setting.
8. Connect the source signal to the amplifier by plugging the RCA cables
or high level inputs into the input jack(s) at the amplifier.
9. Connect the speakers. Strip the speaker wires 5/8" and insert into the
appropriate terminal on the amplifier. Insert the bared wire into the
speaker terminal and tighten the set screw to secure into place. Be sure
to maintain proper speaker polarity. DO NOT chassis ground any of the
speaker leads as unstable operation may result.
10. Perform a final check of the completed system wiring to ensure that all
connections are accurate. Check all power and ground connections for
frayed wires and loose connections which could cause problems from
road vibrations.
– 10 –

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Punch 600Punch 400Punch 800

Table of Contents