POWER TRANSISTOR REPLACEMENT
To replace the Darlington transistors, remove 4 mounting screws on each heat-sink. The TO3
Insulator Sil-Pads should always be replaced when a transistor is reinstalled for any reason.
After replacement the Darlington transistor mounting screws must be torqued to 8 inch pounds.
If a transistor has failed, be certain to test the emitter resistors R11-R14.