FAN DRIVER REPLACEMENT
First check to make sure that all connections to the Main PCA are good.
Next check to make sure that the fan driver transistor Q6 is a BC337G and that it is
installed up-side-down compared to the silk screen on the Main PCA.
Use an Ohm Meter to measure for shorts between the Q6 transistor legs. If a short is
measured, look for a solder bridge between the transistor legs on both sides of the
board. If a short is measured and no solder bridges are found, replace Q6.