Download Print this page

HP Configuring Arrays Reference Manual page 86

Configuring arrays

Advertisement

For controllers that support Auto Replace Drive, setting this value to AutoReplace enables a rebuilt spare
drive to become a data drive in the array. When the failed data drive is replaced, it assumes the role of the
former spare, eliminating the need for a second array rebuild.
Behavior
Dedicated
AutoReplace
OnlineSpare
The value for this option determines whether the array specified previously in the script will be configured
with spare drives.
The interface type for drives and spare drives must match, for example, all SAS or all SATA.
Method mode
Custom
Auto
Split
This command splits RAID 1 or RAID 10 volumes into individual RAID 0 volumes.
Two values are available:
HIDDEN—The driver hides the new logical volume from the OS.
VISIBLE—The new logical volume is visible immediately to the OS.
Logical Drive category
The Logical Drive category has the following options:
ArrayAccelerator (on page 87)
LogicalDrive (on page 87)
CachingLogicalDrive (on page 87)
CachedLogicalDrive (on page 87)
NumberOfParityGroups (on page 87)
PreferredPath (on page 88)
Description
Default value for spares
The spare drive becomes a data drive
when the rebuild is complete.
Possible values
To specify exactly which drives to use as spares,
use the applicable convention (port:ID, box:bay,
or port:box:bay).
To specify only the number of spares (not the
exact IDs), enter that number as the value for this
option. ACU automatically selects only those
drives that are suitable for the array.
To specify that the array should not have spares,
enter None.
Yes (indicating one spare)
No
Default value
In Configure action mode: None
In Reconfigure action mode, ACU
ignores any value entered for this
option and keeps any spares that are
already present in the configuration.
In Configure action mode: Yes
(indicating one spare)
In Reconfigure action mode, ACU
ignores any value entered for this
option and keeps any spares that are
already present in the configuration.