843
Incorrect version of audit received
Cause
The receiver has received audit from the extractor that does not match the version of
audit that the receiver expects.
Effect
The receiver abends.
Recovery
This is an internal error. Contact your service provider.
844
Phase one database synchronization complete
Cause
The updater that generated this message has completed phase one of the online
synchronization operation for its volume on the backup system.
Effect
The updater starts phase two of the online synchronization operation.
Recovery
This is an informational message; no recovery is required.
845
Initialization synchronization completed
Cause
The updater that generated this message has completed its synchronization work for
RDF initialization to an initialization timestamp.
Effect
The updater resumes its normal processing.
Recovery
This is an informational message; no recovery is required.
846
RDF TAKEOVER during database synchronization
Cause
When the updater completed its RDF Takeover operation, it had not yet completed
its role in an online database synchronization.
Effect
The database might not be in a consistent state.
Recovery
There is no recovery. If you lose your primary system during an online database
synchronization, the backup database has not yet been synchronized, and its data therefore
might not be consistent.
847
RDF TAKEOVER during initialization synchronization
Cause
When the updater completed its RDF Takeover operation, it had not yet completed
its role in an INITIALIZE RDF...INITTIME operation.
Effect
The database might not be in a consistent state.
Recovery
There is no recovery. If you lose your primary system while the updaters are trying
to catch up from an INITIALIZE RDF...INITTIME operation, the backup database has not yet
been synchronized, and the data in it therefore might not be consistent.
848
RDF extractor waiting for network reply
Cause
The extractor has sent the maximum number of messages to the receiver and it has
not received any replies for at least five minutes.
Effect
The extractor cannot proceed any further.
Recovery
This is not an RDF problem. You should investigate your Expand network and
take corrective action. If necessary, you can issue a STOP RDF command on both primary and
backup systems to stop the RDF processes in an orderly fashion.
849
TMF Shutdown before phase one of database synchronization