Inverter Settings; Sj700/L700/Sj700B Series - Hitachi NT2021XA Instruction Manual

Easy-sequence programming software
Table of Contents

Advertisement

3.1

Inverter Settings

The following table lists the inverter settings related to the easy sequence function.

(1)SJ700/L700/SJ700B Series

Category
Operation
Selection of easy sequence function
switching
Program run signal
General-purpose input
contacts (8 contacts)
General-purpose output
Input/
contacts (6 contacts)
output
switching
General-purpose analog
inputs (3 terminals)
General-purpose analog
outputs (3 terminals)
Frequency command selection
Command
Operation command selection
switching
Acceleration/deceleration input selection
Other
User-defined variables (32 variables)
3-phase power supply
(200 or 400 V)
PRG
(setting unchangeable)
Selecting
MI1 X (00)
Selecting
MI2 X (01)
Selecting
MI3 X (02)
Selecting
MI4 X (03)
Selecting
MI5 X (04)
Selecting
MI6 X (05)
Selecting
MI7 X (06)
Selecting
MI8 X (07)
Eight digital output terminals
XA (00)
Three analog
XA (01)
input terminals
XA (02)
Item
Terminal name
PRG(FW terminal)
Intelligent input
terminals
1 to 8
Intelligent output
terminals
11 to 15
Intelligent relay output
terminals
AL0 to AL2
O terminal
OI terminal
O2 terminal
FM terminal
AM terminal
AMI terminal
SJ700/L700/SJ700B Series
R
S
T
FW
1
2
3
4
5
6
7
8
CM1
H
0 to 10V
O
0 to 10V
O2
4 to 20mA
OI
L
Input and output terminals available for general-purpose input / output settings
Chapter 3
Interface with the Inverter
Variable notation
Related function
in program
code
-
A017
A017
-
X (00) to X (07)
C001 to C008
Xw
C021 to C025
Y (00) to Y (05)
Yw
C026
XA (0)
-
XA (1)
-
XA (2)
-
C027
YA (0)
YA (1)
C028
YA (2)
C029
SET-Freq
A001
FW, RV
A002
STA, STP, F/R
ACCEL,
P031
DECEL
U(00) U(31)
P100 P131
U
V
W
11
12
13
14
15
CM2
AL0
AL1
AL2
FM
CM1
AM
AMI
L
3-1
Variable/
terminal use condition
-
The PRG terminal is enabled when
A017 = 01.
(The FW function is disabled.)
Function code settings are required.
No setting is required.
Function code settings are required.
Related variables are valid only
when A001 = 07.
Related variables are valid only
when A002 = 01.
Related variables are valid only
when P031 = 03.
The variables can be redefined by
using the digital operator or EzSQ.
I M
Selecting
MO1 Y (00)
Selecting
MO2 Y (01)
Five digital
Selecting
MO3 Y (02)
output terminals
Selecting
MO4 Y (03)
Selecting
MO5 Y (04)
One relay
Selecting
MO6 Y (05)
output terminal
Selecting
YA0 YA (00)
Selecting
YA1 YA (01)
Selecting
YA2 YA (02)
Three analog
output terminals