2 - CHOICE OF AMPLIFIER LOCATION AND COOLING

The GOLDMUND SRI2 amplifier generates a very important amount of heat.
It is mandatory to allow a proper cooling of the heat sink. Avoid any location which is
not properly ventilated and avoid to put on top any equipment sensitive to
temperature.
ATTENTION : The fact that the heat sink can reach high temperature is not
detrimental but favorable to the sonic quality of the unit which is self-protected. It is
perfectly normal that the heat sink becomes too hot to be touched.

3 - AC LINE VOLTAGE

A voltage indication is provided on the back plate of the unit. Check if this is
appropriate for your AC line voltage.
ATTENTION : With a 220V setting, the SRI2 amplifier will function properly for AC
line voltage between 200V and 250V. On the 110V position, the AC mains must
deliver between 95V and 125V. If your AC line voltage is usually out of these
tolerances, please consult your GOLDMUND dealer.
Please check the value of the AC line fuse. This fuse is located on the power cord
receptacle. The lid can be removed with a small screwdriver when the cord is
removed.
Use a 3A slow-blow fuse for 220V and a 5A slow-blow fuse for 110V.