Q-See QC-SERIES User Manual page 12

H.264 network video recorders variable d1 and hd recording options
Hide thumbs Also See for QC-SERIES:
Table of Contents

Advertisement

When the window opens, you will be presented with a list of all conneced devices in the
lower portion. This section, marked Device Added, indicates the status of each device along
with other information about it.
4
IP Address
Port
1
10.1.1.65
Port 1
2
10.1.1.67
Port 2
3
10.1.1.68
Port 4
4
196.219.8.50
4000
IP Search
Add
Device Added
channel
Edit
Delete
Status
1
2
3
4
Delete
Manual Add
PICTURE 2-10
Icon
Meaning
Description
You may edit the settings on this device by double-clicking on it
Editable
This device is connected directly to the NVR and must be physically
Cannot
unplugged to be removed from this list.
Delete
This device may be deleted from the list by checking the box next to
Removable
it and clicking on the Delete button below.
The connected device is operating normally.
Device
Status OK
There is an issue with the connected device that is preventing it from operating
Device
normally.
Error
Clicking on IP Search under the upper portion of the window will generate a list of all devices
that the NVR was able to locate - both directly connected as well as connected to the same
network as your system. Items showing a short IP address beginning with "10" are cameras
directly connected to the NVR and who's IP addresses were assigned by the NVR itself. Care
should be taken that you do not attempt to connect a device that is already connected to the
system as it will create a duplicate video feed and could cause connectivity issues.
22
REMOTE DEVICE
Device ID
Manufacturer
Type
YZC2OC061966
Private
IPC
YZCAU192012
Private
IPC
TC2FW25600095
Private
IPC
Private
None
Filter
IP Address
Port
Device ID
196.610.6.46
37777
10.1.1.67
Port 2
YZCAU192012
10.1.1.68
Port 4
TC2FW25600095
10.1.1.65
Port 1
YZC2OC061966
OK
Cancel
Edit
Double-clicking on a device in the Device Added portion of the window will display
information regarding the connected remote device. Making any changes within this window
will not change anything on the camera or remote device itself. To make those changes, you
will need to access the camera or other remote device (such as a DVR) directly, or through
one of the remote methods described in the Remote Monitoring Guide.
Once you have made those changes, you will need to update the user name and password
within the Edit window. Failing to change these in this window will result in an on-screen
message about incorrect password and may lock you out of the IP camera for a period of 30
minutes in the case of QC-Series cameras - other brands may vary.
It is important that you do not remove the
device you are making the changes upon
from the list of connected devices before
editing the information in the Edit window. If
you later remove the device from the list and
wish to reconnect, you will need to do so
using the Manual Add feature as described
below.
Similarly, if you already know the IP address
and port of the camera, you can use the
Manual Add feature.
IMPORTANT! To avoid connection issues, you should not change the
information within the Edit window unless you have first made those changes
to the remote device itself.
The lower portion of the window shows all devices currently connected to your NVR. If all of
your channels are occupied, you will need to delete one of the connected devices from this
list by selecting the check box next to it and clicking delete. Items with a gray "X" are directly
connected to your NVR and may only be removed by physically disconnecting them from your
system.
Clicking on the IP Search button will create a list of all remote devices that the NVR was able
to detect. You may limit this search to only IP cameras by selecting IPC in the Filter pull-
down. Items being accessed by your NVR over the Internet will not appear in the list at the top
of the window. They must be added manually (see below).
If you have an available channel, you may add a device by selecting the check box next to it
and then clicking Add. Please note that if you changed the default user name and password
for your camera(s) in the Web Service application as described in Chapter 3, you will need to
use the the Manual Add feature instead.
REMOTE DEVICE
4
IP Address
Port
Device ID
Manufacturer
Type
1
10.1.1.65
Port 1
YZC2OC061966
Private
IPC
EDIT
2
10.1.1.67
Port 2
YZCAU192012
Private
IPC
3
10.1.1.68
Port 4
TC2FW25600095
Private
IPC
Channel
1
4
196.219.8.50
4000
Private
Manufacturer
Private
IP Address
None
IP Search
Add
IPC.myq-see.com
Filter
TCP Port
32555
Device Added
User
admin
channel
Edit
Delete
Status
IP Address
Port
Device ID
Password
1
196.610.6.46
37777
Remote Channel
1
2
10.1.1.67
Port 2
YZCAU192012
280
Decoder Buffer
3
10.1.1.68
Port 4
TC2FW25600095
4
Save
10.1.1.65
Cancel
Port 1
YZC2OC061966
Delete
Manual Add
OK
Cancel
PICTURE 2-11
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qcn7001bQcn7002dQcn8001bQcn8002d

Table of Contents