SERVICE AND STORAGE

INFREQUENT SERVICE

If the unit is used infrequently, difficult starting may result. to
eliminate hard starting, run the generator at least 30 minutes every
month. Also, if the unit will not be used for some time, it is a good
idea to drain the fuel from the carburetor and gas tank.

LONG TERM STORAGE

When the generator set is not being operated or is being stored more
than one month, follow these instructions:
1.
Replenish engine oil to upper level.
2.
Drain gasoline from fuel tank, fuel line and carburetor.
3.
Pour about one teaspoon of engine oil through the spark
plug hole, pull the recoil starter several times and replace
the plug. Then pull the starter until you feel the piston is on
its compression stroke and leave it in that position. This
closes both the intake and exhaust valves to prevent the
inside of the cylinder from rusting.
4.
Cover the unit and store in a clean, dry place that is well
ventilated away from open flame or sparks.
NOTE: We recommend always using a fuel stabilizer. A fuel
stabilizer will minimize the formulation of fuel gum deposits during
storage. The fuel stabilizer can be added to the gasoline in the fuel
tank, or into the gasoline in a storage container.
English

SERVICE INFORMATION

CONTACT THE
Pramac America
PRODUCT SERVICE
DEPARTMENT AT
1-800-445-1805
or at www.powermate.com
to obtain warranty service
information or to order
replacement parts or accessories.
HOW TO ORDER REPLACEMENT PARTS
Even quality built equipment such as the electric generator you have
purchased, might need occasional replacement parts to maintain it in good
condition over the years. To order replacement parts, please give the
following information:
1.
Model No. and Serial No. and all specifications shown on
the Model No./Serial No. plate.
2.
Part number or numbers as shown in the Parts List section
of the Insert for your generator model.
3.
A brief description of the trouble with the generator.
NOTE: If replacement parts are required for the engine,
contact one of the engine manufacturer's service centers.
Pramac America
4970 Airport Road
P. O. Box 6001
Kearney, NE 68848
1-800-445-1805
www.powermate.com
8
Customer Hotline 1-800-445-1805

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents