Whirlpool Duet YWED9200SQ0 Use & Care Manual page 7

Electronic electric dryer
Hide thumbs Also See for Duet YWED9200SQ0:
Table of Contents

Advertisement

Available languages

Available languages

Emectrical
Shock Hazard
Plugintoa grounded 4 prong outlet.
Failure t o dosocanresumt indeath oremectrica{
shock.
It is your responsibility
To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in
conformance
with the Canadian Electrical Code, C22.1 -latest
edition and all local codes. A copy of the above codes
standard may be obtained from: Canadian Standards
Association,
178 Rexdale Blvd., Toronto, ON M9W 1R3
CANADA.
To supply the required 4 wire, single phase, 120/240 volt,
60 Hz., AC only electrical supply on a separate 30-amp
circuit, fused on both sides of the line. A time-delay fuse or
circuit breaker is recommended.
Connect to an individual
branch circuit.
This dryer is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-30R
wall receptacle. The cord is 5 ft (1.52 m) in length. Be sure
wall receptacle is within reach of dryer's final location.
4-wire receptacle
14-30R
If using a replacement power supply cord, it is recommended
that you use Power Supply Cord Replacement Part Number
9831317. For further information, please reference the service
numbers located in the "Assistance
or Service" section of this
manual.
GROUNDING INSTRUCTIONS
[]
For a grounded, cord-connected
dryer:
This dryer must be grounded. Hnthe event of malfunction
or breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current. This
dryer is equipped with a cord having an equipment-grounding
conductor and a grounding plug= The plug must be plugged
into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
WARNING:
Hmproperconnection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative or
personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with the
dryer: if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
SAVE THESE INSTRUCTIONS
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foim vent.
Failure to follow
these instructions
can resumt in death
or fire.
WARNING;
To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected
into any gas vent,
chimney, wall, ceiling or a concealed space of a building.
If using an existing vent system
Clean lint from the entire length of the system and make sure
exhaust hood is not plugged with lint.
Replace any plastic or metal foil vent with rigid or flexible
heavy metal vent.
Review Vent system chart. Modify existing vent system if
necessary to achieve the best drying performance.
If this is a new vent system
Vent material
Use a heavy metal vent. Do not use plastic or metal foil vent.
4" (10.2 cm) heavy metal exhaust vent and clamps must be
used. DURASAFE
TM
venting products are recommended.
4" (10.2 cm) heavymetal exhaust vent
DURASAFF Mvent products can be purchased from your
dealer or by calling Whirlpool Parts and Accessories.
For
more information, see the "Assistance
or Service" section of
this manual.
Rigid metal vent
For best drying performance,
rigid metal vents are
recommended.
Rigid metal vent is recommended
to avoid crushing and
kinking.
Flexible metal vent
Flexible metal vents are acceptable only if accessible for
cleaning.
Flexible metal vent must be fully extended and supported
when the dryer is in its final location.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Duet ywed9400sz0Duet ywed9400sw0Duet ywed9400su0

Table of Contents