Alevel f loor w ithamaximum s lope of1in.(2.5 cm)under
entire dryer. Ifslope isgreater than1in.(2.5 cm), i nstall
Extended Dryer Feet K it,Part N o.279810. Clothes m ay not
tumble p roperly andautomatic sensor cycles m ay not
operate c orrectly ifdryer i snotlevel.
For a garage installation, you will need to place the dryer at
least 18 in. (46 cm) above the floor. If using a pedestal, you
will need an additional 6 in. (15.24 cm).
Do not operate your dryer at temperatures
below 45°F (7°C). At
lower temperatures,
the dryer might not shut off at the end of an
automatic cycle. This can result in longer drying times.
The dryer must not be installed or stored in an area where it will be
exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
Installation
clearances
The location must be large enough to fully open the dryer
door.
Dryer Dimensions
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door and
floor moldings.
Additional spacing of 1 in. (2.5 cm) on all sides of the dryer is
recommended
to reduce noise transfer.
Companion appliance spacing should also be considered.
=
(138.81 _m)
38 I,
(96.52 cm)
L
L
]
* Most installations require a minimum 51/2in. (14 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
+
Minimum
installation spacing for custom
undercounter
installation
The dimensions
shown are for the minimum spacing allowed.
Custom undercounter
installation - Dryer only
Minimum
installation spacing for recessed
or closet
installation,
with or without a pedestal
The dimensions shown are for the minimum spacing allowed.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Closet installation - Dryer only
_['--
48 in. 2
(310 cm2) -
24 in.2
(155 cm2)
10"l<- 8_.+/' "t 6"1
(Ocm) (BOom) (Ocm)
3"
7,6 cm)
f
(7,63;m)
I
2
1. Side view- closet or confined area
2. Closet door with vents
Recessed or closet installation - Dryer on pedestal
O" ---+P._F i
27"
_--
0"
(Ocm)
i
(68,6 cm)
--(O
cm)
H
H
/_
!8" mln.
lo' I<- 38_/_' +'l 6"
(Ocm)
(80 cm)
(Ocm)
1
2
!. Recessed area
2. Side view - closet or confined area