Alarm Recording - EverFocus EDSR100 Instruction Manual

Digital single channel recorder
Hide thumbs Also See for EDSR100:
Table of Contents

Advertisement

7.2 ALARM RECORDING

The monitor image will automatically record when alarm occurs and
duration period.
Instant recording and timer recording will stop when an alarm occurs.
Press MENU key and turn the jog dial to select the ALARM
RECORDING SETTING MENU.
MENU
RECORDING OPERATION:
ON: Enables alarm recording,
OFF :Disables alarm recording.
RECORDING SPEED:
Set the recording speed when alarm occurs.
RECORDING QUALITY:
In alarm duration, the recording quality can be set which is different from instant or timer recording.
ALARM – IN TYPE:
Select the type of alarm-in input to be Normal Close (N.C.) or Normal Open (N.O.)
ALARM – RESET TYPE:
Select the type of alarm-reset input to be Normal Close (N.C.) or Normal Open (N.O.)
ALARM DURATION TIME:
Alarm duration from 10 seconds to NON – STOP.
PRE-ALARM OPERATION:
ON: Enables pre-alarm recording,
OFF: Disables pre-alarm recording.
RECORDING SPEED:
Set the recoding speed in pre-alarm duration.
Notice:
The recording quality in pre-alarm duration is the same as recording quality before alarm occurs. If the recorder
is not recording before alarm occurs, the recording quality in pre-alarm duration will be the same as instant
recording quality.
Recording
29
stops
recording at the end of the alarm