Attaching The Unit To The Wall Bracket

If you are using right, left or bottom piping outlet (see page 8) you must wire the
unit before you attach it to the wall bracket.
• Hook the unit to the hangers on top
of the bracket first and then press
the lower left and right side of the
unit against the wall bracket until it is
seated properly.
• Ensure that the unit is level.
• Ensure that the drain hose is in the
proper position.

Wiring The Indoor Unit

You may connect the wires to the indoor unit by opening the Decorative Front
Grille.
• Remove 2 screws that secure the Control Box Cover.
• Connect the wire as shown on the wire diagram located on the control box
cover or refer to the Wiring Diagram Section in this manual.
• Route the interconnecting wires to the
back through the opening in the front as
shown.
• Ensure all terminals are securely
tightened.
INDOOR UNIT INSTALLATION
Control Box
Cover
Wire Diagram
Route the wires through
this opening towards
(Top View)
the back of the unit.
Drain
Hose
Decorative
Front Grille
Screws