To Install: Plumbing - Scotsman DCE33 Series User Manual

Restaurant type ice machine
Hide thumbs Also See for DCE33 Series:
Table of Contents

Advertisement

DCE33
TO INSTALL: Plumbing
The water supply and drain should be roughed
in
and ready at the point of installation. A walt outlet
directly
behind the ice machine
will make
undercounter
installation
easier. All electrical,
water and drain connections
must conform
to local
codes.
Installation
Cautions:
Although
the DCE33
has
been designed
to be serviced
in place, in some
cases it may be necessary
to pull the unit out for
service.
For that reason do not restrict access
to
the cabinet at the front - top and bottom.
Install Unit
lush With Floor
Installations
on a slab:
Use a pump
(DCE33PA-1
B) model and pump the water to the
point of drainage.
Pump models wilt pump 1 story
high.
Installations
over a crawl
space
or basement:
Either gravity drain or pump model units may be
used, if there is not enough
room behind the
machine
for a drain/waste
receptacle,
the drain will
have to be below the floor.
ALL PLUMBING
MUST MEET LOCAL CODES
Note: When
installed
in a corner, the door
swing may be limited due to handle contact
with the wall or cabinet
face.
Shims
If a floor is to be installed
after the ice machine,
shims the thickness
of the floor should be installed
under the DCE33 to keep the machine
level with
the floor. Also, allow 1/8" clearance
on each side
of the cabinet.
From Ice Machine
Normal Drain Line, Pitched
Down From Ice Machine
To Drain
Good Draining
With Trap, Causes Poor Draining
--
o
__
.
With Trap And Vent,
Draining Is Normal
EXAMPLES OF GRAVITY DRAIN TUBE INSTALLATIONS
Poor Draining
Good Draining
June 2000