Scotsman DCE33 Series User Manual page 5

Restaurant type ice machine
Hide thumbs Also See for DCE33 Series:
Table of Contents

Advertisement

TO INSTALL: Plumbing
Free Standing
Cabinet,
Gravity Drain
Model:
All horizontal
runs of drain lines must have a 1/4"
per foot fall. An air gap wilt likely be required
between
the ice machine
drain tube and the
drain/waste
receptacle.
A stand pipe with a trap
below it would be acceptable
for the drain/waste
receptacle.
A floor drain is also acceptable.
FOLLOW
ALL LOCAL PLUMBING
CODES
Poor draining
will cause
a high rate of ice
melting
in the bin.
1. Remove
the kick plate and the access cover
above it.
2. Route the water supply, which should be a 1/4"
O.D. copper tube through
the back of the cabinet
to the front.
3. Install a flare nut and flare the end of the tube.
4. Flush the water line and fasten the flare nut to
the male flare on the inlet water valve.
DCE33
5. Route a 5/8" ID (7/8" OD) drain tube through
the
back panel of the machine
and connect
to the bin
drain fitting at the bottom of the bin. Secure with
hose clamps.
Be certain that the drain tube is pushed
up well
past the barbs on the drain fitting. If needed to
ease installation,
soak the drain hose in hot water
just before connecting
to the fitting.
6. Route the drain tube from the ice machine
to the
drain/waste
receptacle.
Note: if using a long
horizontal
run (more than 5') the drain should
be
vented at back of cabinet.
7. Turn on the water supply and check for leaks.
8. Replace the kick plate and the access cover
above it.
9. Level the unit using the leg levelers.
Water Filter
(Recommended)
Shut Off Valve
Water Inlet
Connection Detail
Floor Drain
INSTALLATION
OF WATER AND DRAIN
January 2002
Page 5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents