30" (76.2 CM) AND 36" (91.4 CM)
RETRACTABLE (POP-UP)DOWNDRAFT VENTSYSTEM
/[ 0._;_1
lC=/O0 0;::_ cJ_,,.,.J.,,...........................
,o.,,., GIICj@
For questions about features, operation/performance,
parts, accessories or service, call: 1-811-253-1311
or visit our website at www,whirlpool,com
In Canada, call 1-811-817-6777
or visit our website at www, whirlpool,ca
SYSTEME DEVENTILATION RETRACTABLE (CLAPET) D E
30" (76,2 CM) ET36" (91,4 CM)---ASPIRATION
PARLEBAS
.
,=
.,+4o ,,, ,,,_,=,+,.........
,, =,
=,
II,,,,,,B_= i ,>,,
._
,<, _ ,,,.......
n,_ uc_o_"_'
• _,_ d _nsUlcs£on et Guide d ul bcst_o_e d.ent_len
Au Canada,
pour
assistance,
installation
ou service,
composer
le 1-800-807-6777
ou visiter
notre
site Web
www.whirlpool.ca
Table of Contents/Table
des matieres .............................................................................
2
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL
USE ONLY.
iMPORTANT
: URE ET CONSERVER CES iNSTRUCTiONS.
POUR UTIUSATION
Ri_SIDENTIELLE
UNIQUEMENT.
LI3ZUB/W103424910

Advertisement

Table of Contents
loading

Summary of Contents for Whirlpool UXD8630DYS0

  • Page 1 For questions about features, operation/performance, parts, accessories or service, call: 1-811-253-1311 or visit our website at www,whirlpool,com In Canada, call 1-811-817-6777 or visit our website at www, whirlpool,ca SYSTEME DEVENTILATION RETRACTABLE (CLAPET) D E 30" (76,2 CM) ET36" (91,4 CM)---ASPIRATION PARLEBAS n,_ uc_o_"_'...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS VENT SYSTEM SAFETY ..............Check Operation ................ INSTALLATION REQUIREMENTS ..........VENT SYSTEM USE ..............Tools and Parts ................Operating Downdraft Vent ............Location Requirements ..............VENT SYSTEM CARE ..............Electrical Requirements ............... Surface of Downdraft Vent ............Venting Requirements ..............
  • Page 3 iMPORTANT SAFETY iNSTRUCTiONS WARNING: TO REDUCE THE RISK OF A RANGE TOP WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC GREASE FIRE: SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: [] Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may [] Use this unit only in the manner intended by the ignite.
  • Page 4: Installation Requirements

    INSTALLATION REQUIREMENTS Gather the required tools and parts before starting installation. Parts Supplied Read and follow the instructions provided with any tools listed • Top trim--stainless here. • End caps (2) • Lower support legs (2) Tools Needed • Undercounter mounting brackets (2) •...
  • Page 5 Product Dimensions Top trim widths: 30" (76.2 cm) 36" (91.4 cm) 131/2`' (34.3 cm) retractable vent height (0.95 cm) 27" (68.6 cm) for 30" (76.2 cm) vent 33" (83.8 cm) for 36" (91.4 cm) vent 51/4"(13.3 cm) for 30" (76.2 cm) vent (21.0 cm) for 36"...
  • Page 6 Countertop Cutout Dimensions IMPORTANT: Countertops with a bull-nosed front edge are not recommended for these installations. Some models require a countertop deeper than 25" (63.5 cm); see the following "Countertop Cutout Dimensions Chart." To avoid mistakes, it is recommended that the cooktop and vent cutouts be drawn on the countertop before making any cutouts. See the Installation Instructions that came with your cooktop for complete cutout dimensions, location dimensions and installation details.
  • Page 7: Electrical Requirements

    Observe all governing codes and ordinances. • If the house has aluminum wiring, follow the procedure below: Ensure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 (latest 1. Connect a section of solid copper wire to the pigtail leads.
  • Page 8: Installation Instructions

    INSTALLATION INSTRUCTIONS Determine which venting method is best for your application. Island Location--Vent System Installed Under a Concrete Vent system can terminate either through the wall or floor. Slab Using PVC Sewer Pipe Island Location Front (Standard) Mounted Blower Motor Rear-Mounted Blower Motor Front (Standard)-Mounted...
  • Page 9: Install Vent System

    To calculate the length of the system you need, add the Example Vent System equivalent feet (meters) for each vent piece used in the system. 31/4'' x 10" (8.3 cm x 25.4 cm) Vent Piece Rectangular 31/4"x 10" (8.3 cm x 25.4 cm) 5.0 ft 2 ft (0.6 m) 90 °...
  • Page 10 Install the right and left undercounter mounting brackets to Attach the support legs to the side of the vent box with the vent box. Slide the keyhole slots over the guide tabs and 4 - 4 x 8 mm screws in each support leg. Adjust to dimension "Y"...
  • Page 11: Rear Mounting--Blower

    Left or Right Venting: Mo$o 1. Using two or more people, place the downdraft vent system on its back. NOTE: Optional blower motor rear mounting position (opposite 2. Remove the 4 screws from the cover plate mounted to the side) for island cabinet locations. The blower motor box face of the motor box and set them aside.
  • Page 12: Complete Installation

    4. Lift the 1¼,, ( 6.4 mm) deep cover off the shoulder screws in the keyhole slots and set the cover aside. 5. Remove the screws from the wire mounting plate. NOTE: The downdraft vent system is supplied with a 3¼" x 10" (8.3 x 25.4 cm) back draft damper and a 6"...
  • Page 13: Make Electrical Connections

    2. Remove 4 screws attaching the terminal box cover. Drill 2 pilot holes through each of the undercounter mounting brackets into the underside of the countertop. Using 2 screws (not provided) of the appropriate length, mount the brackets to the countertop. IMPORTANT: Select a screw length that will not allow the screws to go through the countertop when tightened.
  • Page 14: Check Operation

    2. Feed the power supply cable through the conduit connector and into the terminal box. Electrical Shock Hazard Electrically ground blower. Connect ground wire to green and yellow ground wire in terminal box. D. Black wires Failure to do so can result in death or electrical shock.
  • Page 15: Operating Downdraft Vent

    To Use: NOTE: If a spill occurs on the cooktop that allows liquids to seep inside the downdraft vent, you must turn the downdraft vent off Push and hold the button on top of downdraft vent for a few immediately. It is possible to cause damage to the downdraft seconds, (This slight delay helps avoid unintentional raising...
  • Page 16: Wiring Diagram

    WIRING DIAGRAM © Motor Specifications Power supply 120 VAC Frequency 60 Hz Wattage rating 420 W Amperage 3.7 A Motor Resistance BU/W 21.6 Ohms BU/R 18 Ohms BU/GY 14.3 Ohms ® BU/BK 9.8 Ohms ® %_,_° © Blower Switch Operation Function Contact 1st Speed...
  • Page 17: Assistanceor Service

    Features and specifications on our full line of appliances. For further assistance • Installation information. If you need further assistance, you can write to Whirlpool • Use and maintenance procedures. Corporation with any questions or concerns at: • Accessory and repair parts sales.
  • Page 18: War Ranty

    YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE OR PROVINCE TO PROVINCE. If outside the 50 United States and Canada, contact your authorized Whirlpool dealer to determine if another warranty applies. If you need service, first see the "Troubleshooting"...
  • Page 19: Securite Du Systeme De Ventilation

    SECURITE DU SYSTEME DEVENTILATION Votre securite et celle des autres est tres importante. Nous donnons de nombreux messages de s_curit_ importants dans ce manuel et sur votre appareil m_nager. Assurez-vous toujours lire tous les messages de s_curit_ et de vous y conformer. Ce symbole d'alerte de s_curit_ vous signale les dangers potentiels de d_c_s et de blessures graves &...
  • Page 20 llVlPORTANTES iNSTRUCTiONS DE Sl CURITl AVERTISSEMENT : POUR MINIMISER LE RISQUE AVERTISSEMENT : POUR REDUIRE LE RISQUE D'UN FEU DE GRAISSE SUR LA CUISINIF:RE : D'INCENDIE, CHOC ELECTRIQUE OU DOMMAGES CORPORELS, RESPECTER LES INSTRUCTIONS [] Ne jamais laisser un 616ment de surface fonctionner & SUIVANTES puissance de chauffage maximale sans surveillance.
  • Page 21: Exigences D'installation

    EXIGENCESD'INSTALLATION [)IG, COS Pi_ces fournies Rassembler les outils et pieces necessaires avant d'entreprendre I'installation. Lire et observer les instructions fournies avec • Garniture superieure--acier inoxydable chacun des outils de la liste ci-dessous. • Embouts (2) • Pieds de soutien inferieurs (2) Outillage n_cessaire •...
  • Page 22 Dimensions du produit Largeurs de la garniture 30" (76,2 cm) supdrieure: 36" (91,4 cm) 131/2" (34,3 hauteur de I'_vacuation r_tractable 27" (68,6 cm) pour une _vacuation de 30" (76,2 cm) 33" (83,8 cm) pour une _vacuation de 36" (91,4 cm) 51/4`' (13,3 cm) pour une _vacuation de 30"...
  • Page 23 Plan de travail--Dimensions des ouvertures _ d_couper IMPORTANT : Les plans de travail avec rebord avant arrondi ne sont pas recommandes pour ces installations. Certains modeles necessitent un plan de travail de plus de 25" (63,5 cm); voir le tableau des dimensions de I'ouverture du plan de travail.
  • Page 24: Specifications Electriques

    Observer les dispositions de tousles codes et reglements en • Si le domicile possede un c&blage en aluminium, suivre la vigueur. procedure ci-dessous : Raccorder une section de c&ble en cuivre massif aux S'assurer que I'installation electrique est correcte et qu'elle conducteurs en queue de cochon.
  • Page 25: Instructions D'installation

    INSTRUCTIONS D'INSTALLATION Configuration en lot-Circuit d'6vacuation install_ sous Determiner la methode d'evacuation la plus appropriee. La sortie une dalle de b_ton (utilisation de conduit de PVC pour & I'exterieur du circuit d'evacuation peut se faire a travers le _gout) plancher ou & travers un mur. Configuration en lot Ventilateur mont_ &...
  • Page 26: Installation Du Conduit D'evacuation

    Pour calculer la Iongueur effective du circuit d'evacuation Exemple de circuit d'_vacuation necessaire, additionner les Iongueurs equivalentes (en pieds ou metres) de tousles composants utilises dans le circuit. (1,8 m) Rectangulaire de 31/4 '' x 10" Composant (8,3 cm x 25,4 cm) 2 pi (0,6 m) Raccord coude &...
  • Page 27 Installer sur la caisse du systeme d'extraction les equerres Fixer les pieds de soutien aux c6tes de la caisse du systeme droite et gauche de montage sous le plan de travail. Inserer d'extraction avec 4 vis de 4 x 8 mm pour chacun. Les regler les encoches en trou de serrure dans les languettes guides et la distance "Y"...
  • Page 28: Montage Du Ventilateur & I'arriere

    Sortie par le c6t_ gauche ou le c6t_ droit : 1. A deux personnes ou plus, poser I'arriere du systeme ,Ill _Ss ' I_Y °' '_5_ I d'extraction par le bas face au sol. REMARQUE : Position de montage du ventilateur i I'arriere (cite 2.
  • Page 29: Achever I'installation

    4. Lever le couvercle d'epaisseur 1/4"(6,4 mm) pour le sortir des o fon vis & epaulement dans les encoches en trou de serrure et le mettre de c6te. RI=MAROUI= : Le systeme d'extraction par le bas est livre avec 5. Retirer les vis de la platine de montage du c&ble. un clapet anti-retour de 31/4"x 10"...
  • Page 30: Raccordements Electriques

    2. Oter les 4 vis du couvercle du boitier de connexion. Percer 2 avant-trous & travers les equerres de fixation sous le plan de travail, dans la face inferieure du plan de travail. Avec 2 vis (non fournies) de la Iongueur adequate, fixer les equerres au plan de travail.
  • Page 31: Contr61E Du Fonctionnement

    2. Faire passer le c&ble d'alimentation & travers le connecteur de conduit et dans le boitier de connexion. Risque de choc _lectrique Relier le ventilateur a la terre. Brancher Je fil reli_ a la terre au fiJ vert et jaune reli_ la terre clans Jaboite de la borne.
  • Page 32: Utilisation Du Systeme D'extraction Par Le Bas

    Pour les tables de cuisson & gaz dotees du systeme de un brQleur qui est deja allum& Pour resoudre le probleme de rallumage par detection de flamme, le systeme d'extraction I'allumeur & etincelles qui jette des etincelles continuellement, retractable pourrait disperser la flamme et I'eloigner de diminuer la vitesse du systeme d'extraction retractable ou I'allumeur &...
  • Page 33: Schema De C,&,Blage

    SCHI MA DECABLAGE © Caract6ristiques du moteur Alimentation 120 VCA JA!VE Fr6quence 60 Hz Puissance nominale 420 W Intensit6 3,7 A R6sistance du moteur BU/BL 21,6 ohms BU/R 18 ohms BU/GRIS 14,3 ohms BU/N 9,8 ohms ® ® --O°° © o_ To GRIS GRIS...
  • Page 34: Assistance Ou Service

    I'usine. Veuillez appeler sans frais le Centre pour I'eXperience de la Pour plus d'assistance clientele de Whirlpool Canada LP au : 1-800-807-6777. Si vous avez besoin de plus d'assistance, vous pouvez soumettre par ecrit toute question ou preoccupation &...
  • Page 35: Au Canada

    CONFC:RE DES DROITS JURIDIQUES SPI2CIFIQUES ET VOUS POUVEZ 12GALEMENT JOUIR D'AUTRES DROITS QUI PEUVENT VARIER D'UNE JURIDICTION A UNE AUTRE. Si vous residez & I'exterieur du Canada et des 50 Etats des €:tats-Unis, contactez votre marchand Whirlpool autorise pour determiner si une autre garantie s'applique.
  • Page 36 LI3ZUB/W10342491C 12/11 Printed in Mexico © 2011. All rights reserved. Tous droits reserves. Imprime au Mexique...