lf an extension
cord
is
necessary,
a cord
with
adequate size conductors that is capable
of carrying the current necessary for your
tool must
be used, This will prevent
excessive
voltage drop, loss of power or
overheating.
Grounded tools must use 3-
wire extension cords that have 3-prong plugs
and receptacles.
NOTE: The smaller the gauge number, the
heavier the cord.
RECOMMENDED
SIZES OF EXTENSION
CORDS
120 VOLT ALTERNATING
:URRENT
TOOLS
Tool's
Wire Sizes
in mm 2
Ampere
Rating
Cord Size in A,W,G.
Cord
Length
in Feet
25
50
100 150
3-6
18
16
16
14
6-8
18
16
14
12
8-10
18
16
14
12
10-12
16
16
14
12
12-16
14
12
Cord
Length
in Meters
15
30
60
120
0.75 075 15
25
0.75 1.0 2,5
4,0
0.75 1.0 2.5
4.0
1.0 2.5 4.0
--
* Double-Ended Screwdriver Bit
** Carrying Case
(* = standard equipment)
(** = optional accessories)
Read instruction manual firstT Remove battery pack from the tool before making
adjustments or assembling accessories.
TROUBLE: TOOL WILL NOT START
PROBLEM
1. Battery pack not charged.
2. Battery pack not installed properly.
3. Battery pack temperature is too hot or cold for operation.
4. Burned out switch.
REMEDY
1. If equipped, check battery charge condition lights for charge status.
Charge battery if needed.
2. Confirm battery is locked and secured to the tool.
3. Let battery sit a few minutes or until it reaches normal operating
temperature.
4. Have switch replaced by an Authorized Skil Service Center or Service Station.
TROUBLE: BATTERY PACK WILL NOT CHARGE
PROBLEM
1. Charger not plugged into outlet.
2. Battery pack not completely inserted into charger.
REMEDY
1. Confirm charger is plugged into outlet.
2. Confirm battery pack is inserted into charger completely.