PROBLEM: The walking belt slows when walked on
SOLUTION:
a. Use only a single-outlet surge suppressor that meets all of the specifications described on page 10.
b.
If the walking belt is overtightened, treadmill perfor-
mance may decrease and the walking belt may be-
come damaged. Remove the key and UNPLUG THE
POWER CORD. Using the allen wrench, turn both
rear roller adjustment bolts counterclockwise, 1/4 of a
turn. When the walking belt is properly tightened, you
should be able to lift each side of the walking belt 2 to
3 inches off the walking platform. Be careful to keep
the walking belt centered. Plug in the power cord, in-
sert the key, and run the treadmill for a few minutes.
Repeat until the walking belt is properly tightened.
Rear Roller Adjustment Bolts
c. If the walking belt still slows when walked on, please call toll-free 1-800-4-MY-HOME ® (1-800-
469-4663).
PROBLEM:
The walking belt is off-center or slips when walked on
SOLUTION:
a. If the walking belt is off-center, first remove the key
and UNPLUG THE POWER CORD. If the walking
belt has shifted to the left, use the allen wrench to
turn the left rear roller bolt clockwise 1/2 of a turn; if
the walking belt has shifted to the right, turn the
left bolt counterclockwise 1/2 of a turn. Be careful not
to overtighten the walking belt. Plug in the power
cord, insert the key, and run the treadmill for a few
minutes. Repeat until the walking belt is centered.
b*
If the walking belt slips when walked on, first remove
the key and UNPLUG THE POWER CORD. Using
the allen wrench, turn both rear roller bolts clockwise,
1/4 of a turn. When the walking belt is correctly tight-
ened, you should be able to lift each side of the walk-
ing belt 2 to 3 inches offthe walking platform. Be
careful to keep the walking belt centered. Plug in the
power cord, insert the key, and carefully walk on the
treadmill for a few minutes. Repeat until the walking
belt is properly tightened.
b
PROBLEM:
One of the upper body arms squeaks during use
SOLUTION:
a. Correcting this problem requires a small amount of
white marine grease, available at most hardware
stores. Turn the Resistance Knob (t 09) counterclock-
wise until it can be removed. Remove the Resistance
Cone (108) and the Upper Body Arm (117), along
with the 3/8" Washers (5), Spring Washer (111),
Thrust Washers (112), and Thrust Bearing (113).
(Note: If the Resistance Sleeve [107] or Resistance
Plate [27] comes out of the Resistance Bracket [105]
or Resistance Cone, press it back in.) Apply a thin
layer of white marine grease to the outer surface of
the Resistance Cone (108). Reattach all parts in the
order shown at the right.
105
24