Operation; Starting The Furnace; Turning Off The Furnace; Frozen Water Pipe Hazard - Payne PG9YAB Series Owner's Manual & Installation Instructions

Upflow/horizontal/downflow high efficiency gas furnace
Table of Contents

Advertisement

H
The off-delay
is set by moving
a
jumper
on the control.
The
Wiring Diagram
located
on the inside of the blower
door shows the
various
delay
combinations.
Refer
to Fig. 2 for location
of the
control.
If you
are unsure
how
to set the
Off-delay
Control,
contact
a
Qualified
Service Agency.
Set the room thermostat
slightly
above room temperature.
This will
automatically
signal
the furnace
to start. The inducer
motor will
start, and the hot surface
igniter
will have an orange
glow. After
about 32 seconds
(from the call for heat at the thermostat),
the gas
valve permits
gas to flow to the main burners
where
it is ignited.
When
the flame
is firmly
established,
the igniter
shuts
off. Hot
flames begin
to warm
the furnace's
heat exchanger.
After
a time
delay of 30 seconds,
the furnace
blower
is switched
on.
NOTE:
If the main
burners
fail to ignite,
the furnace
control
system will go through
3 more ignition
cycles. Then, if burners
fail
to ignite, the system
will lockout.
If lockout
occurs,
or the blower
doesn't
come
on, shut down
your furnace
and call a Qualified
Service Agency
for service.
Pressure
Switch
The furnace is equipped
with one or more pressure
switches
to shut
down
the furnace
under
various
flue conditions.
The switches
are
connected
to the furnace by factory supplied
tubing.
Operating
Your Furnace
Keep the blower
access door and all access panels
in place except
for inspection
or maintenance.
Before starting
your furnace be sure you read and understand
all of
the procedures
in this manual.
Check to make sure the furnace filter
is clean and correctly
installed.
Should
overheating
occur
or the gas control
valve
fail to shut
off, shut off the manual
equipment
shutoff
valve
to the furnace
before
shutting
off the electrical
supply.
Extended
Shutdown
1. Set thermostat to lowest
temperature
setting or set thermo-
stat System
Select Switch
to OFF, if so equipped.
2. Turn Manual
Equipment
Shutoff
Valve for furnace
to OFF
position
(at right angle or 90 ° to gas line).
3. Remove
the burner
compartment
door by removing
the two
(2) screws
securing
the door in front and lifting the door up
and outwards.
Removing
the door will expose
the gas con-
trol valve knob.
4. Turn
OFF electric
power
to the furnace
at the disconnect
switch or circuit breaker.
(May be left ON for set-back
type
thermostat
with
batteries,
provided
thermostat
has system
select switch placed
in the OFF position.)
5. Turn the the gas control valve to the OFF position.
See Fig.
3.
6. Reinstall
all doors.
Propane
Gas Model Furnaces
FIRE OR EXPLOSION
HAZARD
Failure to follow
this warning
could
result in property
damage,
personal
iniury or death.
Propane
gas is heavier
than air. Leaking
gas could settle in low
areas such as crawl space.
If you suspect
the presence
of gas,
follow
the instructions
on the cover of this manual.
CARBON
MONOXIDE
POISONING
HAZARD
Failure
to follow
this warning
could
result in personal
injury
or death.
Provisions
for
combustion
and
ventilation
air
must
be
provided
for
in
accordance
with
installation
instructions
supplied
with furnace.
Starting
The Furnace
See Fig. 4 for an illustration
of the gas control valve.
1. Turn
the thermostat to its lowest
temperature
setting
or to
OFF if equipped
with a System
Select Switch.
2. Turn OFF all electric
power
to the furnace
at the disconnect
switch or circuit breaker.
3. Remove
the burner
compartment
door by
removing
the
two(2) screws securing
the door in front and lifting the door
up and outwards.
Removing
the door will expose
the gas
control valve knob.
4. Turn the gas control valve to the OFF position.
See Fig. 3.
5. Wait five (5) minutes
to clear out any gas. If you then smell
gas, STOP!
Follow
the safety information
on the cover
of
this manual.
If you do not smell gas, go to the next step.
6. Turn the gas control valve to the ON position.
See Fig. 3.
7. Reinstall
all doors.
8. Turn ON all electrical
power
to the furnace.
9. Set the thermostat
to the desired
temperature
and the System
Select Switch
to HEAT.
The furnace
will activate
an igniter which
lights the main burners.
Turning
Off The Furnace
Set the thermostat
to the lowest
temperature
setting or set System
Select Switch
to OFF, if so equipped.
If your propane
gas furnace
is installed
in an excavated
or low
lying
area,
we recommend
that
you
contact
your
propane
gas
supplier
about installing
a warning
device that would
alert you of a
gas leak.
Frozen
Water
Pipe Hazard
PROPERTY
DAMAGE
HAZARD
Failure to follow this caution may result in property damage
Furnace may shut down. Do not leave your home unattended
for long periods during freezing weather without turning off
water supply and draining water pipes or otherwise protecting
against the risk of frozen pipes,
Your furnace
is designed
solely to provide
a safe and comfortable
living
environment.
The furnace
is NOT
designed
to ensure
that
water
pipes
will
not freeze.
It is equipped
with
several
safety
devices
that are designed
to turn the furnace off and prevent
it from
restarting
in the event of various
potentially
unsafe conditions.
If your furnace
remains
off for an extended
time, the pipes in your
home
could
freeze
and burst,
resulting
in water
damage.
If the
structure
will be unattended
during
cold weather,
you should
take
these precautions.
1. Turn off the water supply to the structure
and drain the wa-
ter lines if possible
and add an antifreeze
for potable
water
to drain traps
and toilet tanks.
Open
faucets
in appropriate
areas.
-or-