Adjustments - Panasonic KX-F1200 Service Manual And Technical Manual

Plain paper fax with 2-line digital answering system
Hide thumbs Also See for KX-F1200:
Table of Contents

Advertisement

i
KX-r i ZUU
ADJUSTMENTS
1. TABLE
OF TEST EQUIPMENTS
AND TOOL
No.
Test Equipment and Jig Name
1
Oscilloscope
2
CCD Tool
3
Extension Cord
4
Spring Height Tool
Jig No.
PQZZF500M
PQZZ2K12Z, PQZZ8K18Z
PQZZ2F500M
2. ADJUSTING
THE FEEDER PRESSURE
If misfeeding of document, such a multiple feeding or no feeding, occurs frequently, try to adjust the feeder pressure by fol-
lowing steps below.
(2)
A
B C
J
>
(i)
(1) Slide the lever to open the front lid.
(2) Shift the position of the lever by using an instrument with a
pointed end, like a clip or ball-point pen.
Position A: Case of no feeding
Position B: Standard position
Position C: Case of multiple feeding
(3) Close the lid surely by pressing down on both
ends.
,
1.
2.
3,
CONFIRMATION
OF SEPARATION
SPRING
Open the operation grille.
Check the highest level of the separation spring with the
spring height tool (PQZZ2F500M).
Please make sure that the
separation spring does not touch the tool during this
operation. (Both right and left) (See Fig. 1).
Check the lowest level of the separation spring with the
opposite side of the spring height tool. Please make sure that
the separation spring touches the tool during this operation.
(Both right and left) (See Fig. 2).
SPRING HEIGHT TOOL
(PQZZ2F500M)
Fig. 1
NO TOUCH
[.it-_ ©
SEPARATION
SPRING
SPRING HEIGHT TOOL
(PQZZ2F500M)
-77-
Fig. 2
TOUCH
t °°_.
I
_ o_
SEPARATION
SPRING

Advertisement