Maintenance - Husqvarna 1365GN Owner's Manual

Briggs & stratton
Hide thumbs Also See for 1365GN:
Table of Contents

Advertisement

Available languages

Available languages

Maintenance
SPECIFICATIONS
Maximum SurgeWatts .................
8,125 watts
Continuous Wattage Capacity ...........
6,500 watts
Power Factor ..............................
1.0
Rated Maximum Continuous AC Load Current:
At 120Volts .......................
54.2 Amps
At 240 Volts .......................
27. I Amps
Phase.................................
I-phase
Rated Frequency .......................
60 Hertz
FuelTank Capacity ...................
7 U.S.gallons
ShippingWeight .........................
205 Ibs.
GENERAL
MAINTENANCE
RECOMMENDATIONS
The Owner/Operator
is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis;that all discrepancies are corrected; and that the unit
is kept clean and properly stored. NEVER operate
a
damaged or defective generator.
Engine
Maintenance
See
engine
owner's
manual for
instructions.
CAUTION
Used motor
oil has been shown to cause skin cancer in
certain
laboratory
animals.
Thoroughly
wash exposed areas with soap and water.
KEEPOUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES.RETURN
USED OIL TO COLLECTION CENTERS.
Generator
Maintenance
Generator
maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment
where it will not be exposed to excessive
dust, dirt, moisture or any corrosive
vapors. Cooling air
slots in the generator
must not become clogged with dirt,
leaves or any other foreign material.
NOTE: DO NOT use a garden hose to clean generator.
Water can enter engine fuel system and cause problems. In
addition, if water enters generator through cooling air slots,
some of the water wilt be retained in voidsand cracks of
the rotor and stator winding insulation.Water and dirt
buildup on the generator internal windings will eventually
decrease the insulationresistance of these windings.
ENERATOR
WARNING
Disconnect the spark plug wire from the spark plug and place
the wire where it cannot contact spark plug.
Generator
Cleaning
• Use a damp cloth to wipe exterior surfaces clean.
CAUTION
DO NOT expose generator
to excessive moisture,
dust, dirt,
or corrosive
vapors.
DO NOT insert any objects through
cooling slots.
Use a soft bristle brush to loosen caked on dirt or oil.
Use a vacuum cleaner to pick up loose dirt and debris.
Use low pressure air (not to exceed 25 psi) to blow
away dirt. Inspect cooling air slots and opening on
generator.These
openings must be kept clean and
unobstructed.
m

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

1935

Table of Contents