Troubleshooting Guide - Kenmore Power Miser 1533.31412 HA Owner's Manual

Gas water heater
Table of Contents

Advertisement

These guidelines should be used by a qualified service agent, Call Sears Service at 1-800-4-MY-HOME (1-800-469-4663)
for assistance. Inform the associate that this is a "Flammable Vapor Ignition Resistent" Product.
WATER LEAKS
LEAKING T&P VALVE
SMELLY ODORS
PILOT WILL NOT LIGHT
BURNERWILL
NOT
STAY LIT
PILOT OUTAGE
Improperly sealed, hot or cold supply connection,
relief valve, drain valve, or thermostat threads.
Leakage from other appliances
or water lines.
Condensation
of flue products.
Thermal expansion
in closed water system.
Impropedy seated valve.
High sulfate or mineral content in water supply.
Bacteria in water supply.
Gas control knob not positioned
correctly.
Main gas supply off.
Igniter tip more than 1/8" from pilot hood.
Thermocouple
malfunction.
Thermocouple
TOO malfunction.
Melted insulation on ignitor wire or shorting
of ignitor wire.
High ambient room temperature.
Wire disconnected
from spark ignitor.
Broken electrode or electrical wire.
Piezo Ignitor generator fails to operate or
malfunctions.
Thermocouple
TOO malfunction.
High ambient room temperature.
Dirty or clo_,ged air intake screen.
Flame arrestor openings blocked.
NOTENOUGH
HOTWATER
WATER TOO HOT
Thermostat
set too high.
WATER HEATERSOUNDS
Condensation
dripping on burner.
SIZZLING - RUMBLING
Sediment or calcium in bottom of heater tank.
SOOTING
Improper combustion.
VENTGASODORS
Defective Gas Control.
Dirty pilot burner.
Dirty or clogged air intake screen.
Thermocouple
tip is not in contact with pilot flame.
Thermocouple
malfunction.
Thermocouple
TOO malfunction.
Defective Gas Control.
Heater not lit or thermostat not on.
Thermostat
set toe low.
Heater undersized.
Low gas pressure.
Incoming water is unusually cold.
Leaking hot water pipes or fixtures.
High temperature
limit switch activated.
Lack of supply air.
Impropedy installed vent piping.
Downdraft.
Poor combustion.
Tighten threaded connections.
Inspect other appliances
near water heater.
Refer to CONDENSATION.
Install thermal expansion tank (DO NOT plug T&P valve).
Check relief valve for proper operation
(DO NOT plug T&P valve).
Drain and flush heater thoroughly,
then refill.
Chlorinate or aerate water supply.
Refer to LIGHTING INSTRUCTIONS.
Turn on main gas shutoff valve,
Adjust ignitor tip.
Replace pilot assembly.
Replace pilot assembly.
Contact Sears Service to determine cause.
Contact Sears Service to determine cause.
Reconnect
wire connector to spark ignitor.
Replace pilot assembly.
Replace Piezo Ignitor generator.
Replace pilot assembly.
Contact Sears Service to
determine cause.
Clean and reinstall air intake screen.
Contact Sears Service to
determine cause.
Replace Gas Control.
Clean pilot assembly.
Clean and reinstall air intake screen.
Insert themlocouple
correctly.
Replace pilot assembly.
Replace pilot assembly.
Replace Gas Control.
Refer to LIGHTING INSTRUCTIONS.
Refer to TEMPERATURE REGULATION.
Reduce hot water use.
Contact your gas supplier.
Allow more time for heater to re-heat.
Have plumber check and repair leaks.
Contact Sears Service to
determine cause.
Refer to TEMPERATURE REGULATION.
Refer to CONDENSATION.
Clean sediment from tank. Refer to DRAINING
instructions
in Maintenance
section of manual.
No adjustment available. Contact Sears Service
to determine
cause.
Contact Sears Service to determine cause.