Filling The Water Heater; Venting; Temperature Pressure Relief Valve - Kenmore Power Miser 1533.31412 HA Owner's Manual

Gas water heater
Table of Contents

Advertisement

Watertemperature over125°F
(52°C) c ancause severe burns
instantly resulting insevere i njury
ordeath
Children, the elderly, a nd the
physically o r mentally d isabled
areathighest risk forscald injury.
Fee/waterbeforebathingor
showering
Temperature
limiting valves are
available
Read instruction manual forsafe
temperature
setting.
Never u se this water h eater unless i tiscompletely fullofwater.
Toprevent damage t othetank, t hetankmustbefilledwith
water. Water must flow from thehot w ater faucet before t urning
"ON" g astothewater h eater.
Tofillthewater h eater with water:
• Close thewater h eater d rain valve byturning t hehandle t o
theright ( clockwise).
The drain valve isonthelower front o f
thewater b eaten
• Openthecoldwatersupply valveto thewaterheater.
NOTE: The cold water supply valve must be left open when
the water heater is in use.
The temperature-pressure
relief valve must
be manually
operated
at least once a year.
Caution
should be taken to
ensure that (1) no one is in front of or around the outlet of the
temperature-pressure
relief valve discharge line, and (2) the
water manually discharged will not cause any bodily injury or
property damage because the water may be extremely hot.
If after manually operating the valve, it fails to completely reset
and continues
to release water, immediately
close the cold
water inlet to the water heater, follow the draining instructions,
and replace the temperature-pressure
relief valve with a new
one,
HOT WATER
OUTLET
COLD WATER
INLET
SHUTOFF
VALVE
TEMPERATURE*PRESSURE
RELIEF VALVE
(OPTIONAL TOP T & P RELIEF
VALVE NOT SHOWN)
DISHCARGE PIPE
DO NOT CAP OR PLUG)
To insure complete
filling of the tank, allow air to exit by
opening the nearest hot water faucet.
Allow water to run
until a constant flow is obtained.
This will let air out of the
water heater and the piping.
Check all water piping and connections for leaks.
Repair
as needed.
Venting
Breathing
Hazard - Carbon
Monoxide
Gas
• Vent dampers
must be certified
ir_accordance with ANSI Z21 6&
• Vent damper must permit proper
drafting of water heater.
• Install properly sized venting.
• Do not
install
without
venting
outdoors.
• Do not install without drafthood.
• If
common
vented
install
in
accordance with NFPA 54
• Be alert for obstructed or deterio-
rated
vent
system
to
avoid
serious injury or death
Breathing carbon monoxide can cause brain damage or
death Always read and understand instruction manual
VENT DAMPERS
- Any vent damper, whether it is operated
thermally or otherwise must be removed if its use inhibits proper
drafting of the water heater.
FIGURE16.
Filling the Water Heater
Property
Damage
Hazard
• Avoid water heater damage.
• Fill tank with water before operating
Thermally
Operated
Vent Dampers: Gas-fired water heaters
having thermal efficiency
in excess of 80% may produce a
relatively low flue gas temperature.
Such temperatures
may
not be high enough to properly open thermally operated vent
dampers.
This would cause spillage
of the flue gases and
may cause carbon monoxide poisoning.
14
Vent dampers must bear evidence of certification as complying
with the current edition
of the American
National
Standard
ANSI Z21.68 (ANSI Z21.66 & 67, respectively, cover electrically
and mechanically
actuated vent dampers).
Before installation
of any vent damper, consult your local Sears Service Center or
the local gas supplier for further information.