Water Filter Certifications - Jenn-Air JFC2290VEP5 User Instructions

Table of Contents

Advertisement

Available languages

Available languages

Is the water pressure
at least 35 psi (241 kPa)? The water
pressure to the home determines the flow from the dispenser.
See "Water Supply Requirements."
Water filter installed on the refrigerator? Remove filter and
operate dispenser. If water flow increases, the filter may be
clogged or incorrectly installed. Replace filter or reinstall it
correctly.
Refrigerator
door closed completely?
Close the door firmly.
If it does not close completely, see "The doors will not close
completely,"
earlier in this section.
Recently
removed the doors?
Make sure the water
dispenser wire/tube assembly has been properly reconnected.
See "Refrigerator Door(s) and Drawer."
Reverse osmosis water filtration system connected to
your cold water supply? This can decrease water pressure.
See "Water Supply Requirements."
Water is leaking from the dispenser system
NOTE: One or two drops of water after dispensing
is normal.
Glass not being held under the dispenser
long enough?
Hold the glass under the dispenser 2 to 3 seconds after
releasing the dispenser lever.
New installation?
Flush the water system. See "Water
Dispenser."
Recently changed water filter? Flush the water system. See
"Water Dispenser."
Water on the floor near the base grille? Make sure the water
dispenser tube connections are fully tightened. See
"Refrigerator
Door(s) and Drawer."
Water from the dispenser
is warm
NOTE: Water from the dispenser is only chilled to 50°F (10°C).
New installation?
Allow 24 hours after installation for the
water supply to cool completely.
Recently dispensed
large amount of water? Allow 24 hours
for water supply to cool completely.
Water not been recently dispensed?
The first glass of water
may not be cool. Discard the first glass of water.
Refrigerator connected to a cold water pipe? Make sure
the refrigerator is connected to a cold water pipe. See "Water
Supply Requirements."
WATERFILTER CERTIFICATIONS
Trademark/Model
Designation
UKI:8001
AXX-750
469006-750
67003523-750
Manufacturer:
Cuno
State of California
Department
of Public Health
Water Treatment Device
Certificate Number
03- 1583
Dat_ Issued:
September
16, 2008
Date Revised:
April 22, 2009
Cysts
Turbidity
Organic
Contaminahts
Atrazine
Lindane
Carbofuran
p-dichlorobenzene
,
Toxaphene
Tetrachloroethylene
Rated
Service
CapaciD':
750 gal.
Rated
Service
Flow:
0.78 gpm
Conditions
of Certification:
Do ilo( use where
water is microbiologically
unsalb
or wilh water o[" ur&nown
quality,
except
that systems
certified
lbl cys_ reduction
may be used on disJnl_ctcd
waters
that may contain
Iilterable
cysts
State of California
Department
of Public tlealtb
Water
Treatment
Device
Certificate Number
09- 1979
Date Issued:
May
8, 2009
Trademark/Model
Designation
Replacement
Etenlents
UKF8001
AXX-200
UK F800
Manufacturer:
('uno In_
a3M ('ompally
The _vater treatment
device(s)
)isted on this e_rtfficate
|la_e
met the testing
_:equire)gnents
pursuant
to Section
116830
of the Health
and
Safety
_}ode lor the |Mlowin8
health
related
eontaminanI_:
Microbiological
Contaminants
and
"1urbiditv
Cyst_
Turbidity
Organic
Contaminants
Atrazine
Benzene
Carbofuran
Chlorobenzene
Endrm
Ethy/bcnzene
Lindane
o-dichlorobenzcnc
p-dichlorobenzcne
TetrachIoroethylcne
I'oxaphcne
Rated
Service
Capacity:
200 gal
Rated
Service
Flow:
0.78 gpm
Conditions
of Certification:
Do not use where
water is microbiologically
unsali_ or with watel
of unknown
qua]fly,
except
that systems
certil_cd
for cyst reduction
may be used on disinfected
waters that may contain
fiherabIe
cysts•
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents