Note: Upon reassembly
of the fan cover it
best to line up the fan cover and diffuser and
set motor upright on bench and "tap" around
the perimeter
of the diffuser until the fan cover
seats. This will eliminate tapping directly on
the fan cover which could dent and cause the
fan to rub.
7. Remove the fan nut by turning clockwise.
Armature shaft has a screwdriver
slot.
8. Remove fan and check for wear at the
hub.
9. Remove two screws which secure upper
motor housing and remove field and arma-
ture.
Note: On some models it will be necessary to
remove the threaded
balancing
ring on the
top of the motor. This ring was used to bal-
ance the motors in production.
It is not neces-
sary to replace this ring upon reassembly
of
the motor. Both service and production motors
are now produced without this ring.
Upon reassembly
be sure motor mount is
positioned properly.
N. Speed Control
(where applicable)
Note: The speed control is an integral part of
the motor cover assembly.
This assembly
includes the cover, speed control and required
lead wires.
1. Remove motor cover (step 1, item F).
2. Disconnect
the appropriate
leads and
remove the motor retainer assembly (4
crews).
3. Replace motor retainer assembly com-
plete.
Note: When reattaching
motor retainer be
careful not to pinch furniture guard/seal.
O. Thermal
Protector
(PowerMAX
units)
The Thermal protector is held in position with
a clip located on the rear wall near the motor
exhaust.
Remove clip and disconnect
leads at insulated
terminals to remove.
P. Receptacle
assembly
1. Remove motor cover (step 1, item F).
2. Disconnect leads.
3. Remove cord channel cover.
a. Remove the one screw, grasp cover at
receptacle
end and pull free. Release tabs
from main body, lift up and out.