GROUNDING
THE
G EN ERATO R
The National Electrical Code requires that the frame and
external electrically conductive parts of this generator be
properly connected to an approved earth ground. Local
electrical codes may also require proper grounding of the
unit. For that purpose, a GROUNDING WING NUT is
)rovided on the generator end (Figure 3).
Grounding
Wing Nut
Generally, connecting a No. 12AWG (American Wire
Gauge) stranded copper wire to the grounding wing nut
and to an earth-driven copper or brass grounding rod
(electrode) provides adequate protection against electrical
shock. Be careful to keep the grounding wire attached after
connecting the stranded copper wire. However, local codes
may vary widely. Consult with a localelectrician for
grounding requirements in your area.
Properly grounding the generator helps prevent electrical
shock if a ground fault condition exists in the generator or
in connected electrical devices, especially when the unit is
equipped with a wheel kit. Proper grounding also helps
dissipate static electricity, which often builds up in
ungrounded devices.
OPERATING
THE
G EN ERATO R
A
AUTION!
NEVER start or stop the engine
with electrical loadsconnected to the receptacles
AND with the connected devices turned ON.
Starting
the Engine
Disconnect all electrical loadsfrom the generator. Use the
following start instructionsteps by numerical order:
I.
Turn the fuel valve to the "On" position (Figure 4).
Fuel Valve is shown
in the On position
2.
Placethe choke lever in the "Choke"
position
(Figure 5).
/
7