Generac Portable Products 9777-3 Owner's Manual page 7

4000 watt extended life generator
Table of Contents

Advertisement

GROUNDING
THE
GENERATOR
The National Electrical Code requires that the frame and
external electrically conductive parts of this generator be
properly connected to an approved earth ground. Local
electrical codes may also require proper grounding of the
unit. For that purpose, a GROUNDING WING NUT is
provided on the generator end (Figure 3).
I_I_'_L:I_
[eL_l
_"_a
Wing Nut
Generally, connecting a No. 12AWG (American Wire
Gauge) stranded copper wire to the grounding wing nut
and to an earth-driven copper or brass grounding rod
(electrode) provides adequate protection against electrical
shock. Be careful to keep the grounding wire attached after
connecting the stranded copper wire. However, local codes
may vary widely. Consult with a local electrician for
grounding requirements in your area.
Properly grounding the generator helps prevent electrical
shock if a ground fault condition exists in the generator or
in connected electrical devices, especially when the unit is
equipped with a wheel kit. Proper grounding also helps
dissipate static electricity, which often builds up in
ungrounded devices.
OPERATING
THE
GENERATOR
_
CAUTION!
Never start or stop unit with
electrical loads connected AND with the connected
devices turned ON.
Starting
the Engine
Disconnect all electrical loads from the generator. Follow
these start instruction steps in numerical order:
I.
Turn the fuel valve to the "On" position (Figure 4).
2.
.
4.
Fuel Valve is shown in
the "On"
position
Make sure the Idle Control switch is in "Off" position
(Figure 5).
IDLE
Set the Run/Stop switch to "Run" position (Figure 6).
Placethe choke lever in the "Full" choke position
(Figure 7).
"Full" choke
Position